Installation and Operation Guide
Drinking Water Systems
EV3070-43 Rev W DE06
Thank you for purchasing an Everpure commercial-grade water
ltration system for your home. With your Everpure system, you
get premium quality water direct from your tap that’s great-tasting,
healthful and convenient for you and your family.
Specifi cations:
For Cold Water Use Only
Temperature: 35-100°F (2-38°C)
Min.-Max. Working Pressure: 10-125 psi (0.7-8.6 bar)
Service Flow Rate: 0.5 gpm (1.9 Lpm)
H 1200 customers: Instructions for installing the H-1200 begin on page
4 of this Installation and Operation Guide.
MULTIPLE APPLIANCE CONNECTIONS: You can also connect your
Everpure Filter to several water using appliances, such as the
refrigerator for ice and water, an instant hot dispenser or chiller, or a
plumbed-in coffee brewer. Install connection “tees” (available from
any hardware / plumbing supply) in the water line between the fi lter
and the faucet adaptor, and run new tubing to each appliance.
We do NOT recommend connecting the fi ltered water to a commercial
ice maker, since these appliances require fl ow and volume beyond the
design limits of your under-sink fi lter system.
The Owner’s Guide Is Applicable For The Following
Everpure Filter Models:
Model H-54
Rated Capacity:
750 Gallons (2835 Liters)*
Model H-104
Rated Capacity:
1,000 Gallons (3780 Liters)*
Model H-300
Rated Capacity:
300 Gallons (1140 Liters)*
Model H-300-HSD
Rated Capacity:
300 Gallons (1140 Liters)*
Model H-300+M
Rated Capacity:
500 Gallons (1892 Liters)*
Model H-1200
Rated Capacity:
1,000 Gallons (3780 Liters)*
* For optimum performance, cartridge replacement is required once a year,
or sooner if fl ow becomes too slow for convenience, or if the unit’s rated
capacity is reached.
BASIC INSTALLATION INSTRUCTIONS
TOOLS NEEDED FOR INSTALLATION
Phillips Screwdriver
Wrench
Utility Knife
Measuring Tape
Pencil
Open Carton & Inspect Parts
Installation Parts
Key Description Part No.
1 QL3 Filter Head EV9258-01
2 Filter Cartridge (varies)
3 2 Screws w/ Locking Washers EVxxxx-xx
4 Angle Stop Valve Adaptor EV3121-20
5 Tubing, 1/4" poly A08601-19
6 Elbow Fitting Pack Restrictor EV3081-68
7 Tefl on
®
Tape EV3121-19
8 Faucet Connector EV3121-35
9 Everpure Filter Timer EV9075-70
1.
WATER FILTER MONITOR
www.e
ver
pure.co
m
1
WARNING
The Universal Plumbing Code adopted by over 20
states, and other specifi c state and county codes prohibit the use of
saddle valves and their use is never recommended. You must adhere
to your state / local plumbing codes. Consult your licensed plumber if
you have related questions.
WARNING
Do NOT use copper tubing with the John Guest Fittings
provided with your Everpure Filter System. Copper tubing may appear
to fi t, but water leaks will develop over time and use. If copper tubing
is required, you must use copper compression fi ttings available from
any hardware/plumbing supply.
1
2
3
4
5
6
7
8
9
EVERPURE TECHNICAL SERVICES (800) 942-1153 Is available to assist you with any installation or parts problem.
Help is available from 7:00 AM – 6:00 PM Central Standard Time (Monday – Friday Only)
Question and Answer IconNeed help?

Do you have a question about the Everpure H-54 and is the answer not in the manual?

Everpure H-54 Specifications

General IconGeneral
BrandEverpure
ModelH-54
CategoryWater Filtration Systems
LanguageEnglish

Summary

Basic Installation Instructions

Tools Needed for Installation

Lists necessary tools for system installation.

Open Carton & Inspect Parts

Guide to unpacking and checking system components.

Verify Under-Sink Mounting Location

Specifies optimal placement and clearance for the filter head.

Mount Filter Head Under Sink

Instructions for securing the filter head assembly.

Attach Inlet Water Supply

Steps for connecting the water source to the filter head.

Attach Filtered Water to Sink Faucet

Connects the filtered water line to the faucet.

Install and Flush Filter Cartridge

Steps for inserting and flushing the new filter cartridge.

Optional Filter Monitor Installation

Details for installing the H300+M filter system monitor.

H-1200 System Installation

Verify Under-Sink Mounting Location (H-1200)

Mounting location for the H-1200 dual filter head.

Mount Filter Head Under Sink (H-1200)

Securing the H-1200 dual filter head assembly.

Filter Cartridge Maintenance

Cartridge Change Instructions

Procedures for replacing the filter cartridge.

Start Up Procedure

Steps after cartridge replacement, including flushing.

NSF Certifications and Performance

Standard No. 42: Aesthetic Effects

Performance data for aesthetic water quality improvements.

Standard No. 53: Health Effects

Performance data for health-related contaminant reduction.

Limited Warranty Information

One-Year System Warranty

Details the warranty for replaceable elements.

Five-Year System Warranty

Covers the entire system excluding replaceable elements.

Related product manuals