EasyManua.ls Logo

evertz EMX Series - User Manual

Default Icon
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EMX Series Multiframes
User Manual
© Copyright 2011 - 2021
EVERTZ MICROSYSTEMS LTD.
5292 John Lucas Drive
Burlington, Ontario
Canada L7L 5Z9
Phone: +1 905-335-3700
Sales: sales@evertz.com Fax: +1 905-335-3573
Tech Support: service@evertz.com Fax: +1 905-335-7571
Web Page: http://www.evertz.com
Version 1.6, Jan 2021
The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of
purchasers of the EMX Series Multiframes. Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the
operation of the EMX Series Multiframes. Due to on going research and development, features and specifications in this manual are subject to
change without notice.
All rights reserved. No part of this publication may be reproduced without the express written permission of Evertz Microsystems Ltd. Copies of
this manual can be ordered from your Evertz dealer or from Evertz Microsystems.
Question and Answer IconNeed help?

Do you have a question about the evertz EMX Series and is the answer not in the manual?

Overview

The EMX Series Multiframes are advanced rack frames designed to house Evertz EMR series routers, EMC master controllers, and other high-density system products. These frames are available in three sizes: EMX1-FR, EMX3-FR, and EMX6-FR, each offering varying capacities and features to meet the demanding needs of television studios.

Function Description:

The EMX Series Multiframes serve as a robust and flexible housing solution for modular processing cards, offering high-density capacity to conserve equipment rack space. They are designed to accommodate a range of Evertz modules, providing power, cooling, and a high-speed busing and control system for modular applications. The frames support both main and redundant frame controllers (EMX-FC) to provide essential reference, Ethernet control, and serial control functionalities for specific applications. Each slot within the frame is individually configurable for inputs and outputs, allowing for tailored system configurations. The front-loading design facilitates easy extraction and replacement of power supplies and active modules without disrupting performance or requiring rear access for re-cabling.

Important Technical Specifications:

EMX6-FR:

  • Dimensions: 19.0" W x 10.5" H x 15.75" D (483mm W x 266mm H x 400mm D)
  • Module Capacity: 15 single-slot EMR series modules
  • Power Supply: Auto-ranging 100 ↔ 240 VAC, 50/60 Hz
  • Max Operating Current: 9.5 A (@ 115 VAC nominal), 4.0 A (@ 220 VAC nominal)
  • Max Power Consumption: 850 W
  • Max Module Load: 650 W (40 W per slot)
  • Weight (Approx.): 34.8lbs (15.8kg) empty with 2 power supplies; 64.0lbs (29kg) full with 2 power supplies, all slots occupied.
  • Cooling: Designed for up to 650 watts of processing power. Features front and rear fans for power supply cooling, and interior cooling channels for modules.
  • Safety Compliance: CSA Listed to CSA C22.2 No. 60065-03, UL 60065-03, IEC 60065-(2001-12) 7th Edition. Complies with CE Low voltage Directive 93/68/EEC.
  • EMC Compliance: Complies with FCC part 15, class A; Complies with EU EMC directive 89/336/EEC.

EMX3-FR:

  • Dimensions: 19" W x 5.25" H x 15.75" D (483mm W x 133mm H x 400mm D)
  • Module Capacity: 5 single-slot EMR series modules
  • Power Supply: Auto-ranging 100 ⇔ 240 VAC, 50/60 Hz
  • Max Operating Current: 4.6 A (@ 100 V/60Hz), 1.85A (@ 240 V/50Hz)
  • Max Power Consumption: 450 W
  • Max Module Load: 360 W (24 W per slot)
  • Weight (Approx.): 17.4lbs (7.9kg) empty with 2 power supplies; 32.0lbs (14.5kg) full with 2 power supplies, all slots occupied.
  • Cooling: Designed for up to 360 watts of processing power. Features front and rear fans for power supply cooling, and interior cooling channels for modules.
  • Safety Compliance: CSA Listed to CSA C22.2 No. 60065-03, UL 60065-03, IEC 60065-(2001-12) 7th Edition. Complies with CE Low voltage Directive 93/68/EEC.
  • EMC Compliance: Complies with FCC part 15, class A; Complies with EU EMC directive 89/336/EEC.

EMX1-FR:

  • Dimensions: 19.0" W x 1.75" H x 18.75" D (483mm W x 45mm H x 477mm D)
  • Module Capacity: 2 single-slot EMX series modules
  • Power Supply: Auto-ranging 100 ⇔ 240 V AC, 50/60Hz
  • Max Operating Current: 8.5 A (@ 100V/60Hz), 3.0 A (@ 240V/50Hz)
  • Max Power Consumption: 600 W
  • Max Module Load: 140 W (70 W per slot)
  • Weight (Approx.): 15 lbs (6.8kg) empty with 2 power supplies; 22.0lbs (10kg) full with 2 power supplies, all slots occupied.
  • Cooling: Designed for up to 140 watts of processing power. PSU's are cooled with internal fans. Module cooling is provided by fans mounted to the front panel.
  • Safety Compliance: CSA Listed to CAN/CSA-C22.2 No. 60950-1-07, Amendment 1:2011(MOD); ANSI/UL Std. No. 60950-1-2011. Complies with CE Low voltage Directive 2004/108/EC.
  • EMC Compliance: Complies with FCC part 15, class A; Complies with EU EMC directive 89/336/EEC.

General Specifications:

  • Operating Temperature: 0-40°C
  • Power Supply Configuration: 1 supply standard, optional redundant supply requires separate inlet. IEC 60320 connector.
  • Frame Controller: EMX-FC provides two network connections (RJ-45) and two references (BNC). Ref 1 is main, Ref 2 is backup.
  • Status Indicators: PSU status LED (green for healthy, off for malfunction), Local Error/Failure LED (red for frame status fault, off for normal).

Usage Features:

  • High-Density Design: Optimizes rack space utilization.
  • Hot-Swappable Components: Redundant switching power supplies and cooling fans can be replaced without compromising signal integrity.
  • Front-Loading Access: Modules, power supplies, and fans can be extracted from the front, eliminating the need for rear access or re-cabling.
  • Auto-Ranging Power Supplies: Compatible with 100-240 VAC at 50/60 Hz.
  • Redundant Frame Controller: EMX3-FR and EMX6-FR models support optional redundant EMX-FC for enhanced reliability.
  • Genlock References: Two BNCs for connecting separate genlock references for compatible modules.
  • Network Configuration: Basic network settings for the EMX-FC can be configured via a serial connection using Tera Term, allowing for IP address, netmask, and gateway setup.
  • ESD Precautions: Instructions for handling modules to prevent electrostatic discharge damage, including wearing an ESD strap and using a safe work area.
  • Restricted Access Area: Intended for use in areas accessible only by skilled and authorized personnel.
  • Front Panel as Fire Enclosure: The front panel should remain closed except during servicing to maintain its function as a fire enclosure.

Maintenance Features:

  • Cooling System: Designed with dedicated cooling for power supplies and modules. Fan inlets and exhaust openings must be kept free of obstructions to ensure adequate cooling. The front panel must be securely mounted for proper module cooling.
  • Power Supply Status Indicators: LEDs on the power supplies provide visual feedback on AC power status, DC power presence, and fault conditions (e.g., over temperature, over voltage, over current, fan error). The FRAME STATUS LED indicates the overall health of the frame.
  • Fuse Replacement: For EMX3-FR and EMX6-FR, fuses are located inside the power entry module and can be replaced using a small screwdriver. It is crucial to replace fuses with the correct value marked on the rear panel. (Not applicable to EMX1-FR).
  • Power Supply Replacement: Power supplies are complete assemblies including cooling fans. In case of malfunction, the entire assembly can be replaced. For EMX3-FR and EMX6-FR, power supplies are hot-swappable and secured by a mounting screw at the rear. For EMX1-FR, the front panel must be removed, and a locking tab released to remove the PSU.
  • Module Installation/Removal: Modules are installed by aligning them with card guides and pressing them firmly into rear panel connectors. They are removed by pressing down the card ejector.
  • Instructional Safeguards: Warning labels are attached to devices to alert users to potential hazards such as hot surfaces, shock hazards, and multiple power sources. Servicing should only be performed by qualified personnel.
  • Battery Safety: Warnings regarding the danger of explosion if batteries are incorrectly replaced, emphasizing replacement with the same or equivalent type and proper disposal of used batteries.