Page #43 background imageLoading...
Page #43 background image
EQT Router User Manual
Revision 1.9.1 Page 29
Note: The default IP addresses for Router component and Control panel
component always stay the same e.g. (Router 192.168.9.190 and Panel
192.168.9.193)
To change the IP address of the components via Ethernet, follow the instructions below.
1. For the EQT:
1. Telnet to port 4000 of the EQT IP address (i.e. telnet 192.168.9.190 4000).
2. Once the configuration menu is displayed, select the Network Settings menu.
3. Follow the on-screen instructions to set the IP address.
2. For the ACO2 Slot1 (EQT-1602 and EQT-3204 CS version only):
1. Telnet to the IP address of the clean/quiet switch component (i.e. telnet 192.168.9.191)
2. Once prompted with the boot menu, you will be asked for a Login and Password. Use
config for username and password.
3. Once logged in to the main menu, select the Network Setup menu
4. Follow the on-screen instructions to set the IP address
5. Once finished, exit the screen and exit the main menu using the x to ensure the changes are
saved to flash
3. For the ACO2 Slot 2 (3204 CS version only):
1. Telnet to the IP address of the clean/quiet switch component (i.e. telnet 192.168.9.192)
2. Once prompted with the boot menu, you will be asked for a Login and Password. Use
config for username and password.
3. Once logged in to the main menu, select the Network Setup menu
4. Follow the on-screen instructions to set the IP address
5. Once finished, exit the screen and exit the main menu using the x to ensure the changes are
saved to flash
4. For the Control Panel:
1. Telnet to the IP address of the control panel component (i.e. telnet 192.168.9.193)
2. Once the configuration menu is displayed, select the Network Configuration menu
3. Follow the on-screen instructions to set the IP address
To change the IP address of the components via Serial, follow the instructions below
1. For the EQT:
1. Connect the serial cable to “DB9-1 F of the breakout cable.
2. Set the hyperterminal parameters to 115200,8, none, 1, none.
3. Once prompted with the boot menu, you will be asked for a Login and Password. Use root
for username and evertz for password.
4. At the prompt type “ telnet localhost 4000
5. Once logged in to the main menu, select Network Settings menu