PUMP FED INSTALLATION INSTRUCTIONS
14
CLEANING YOUR NEXUS 220 - PUMP FED INSTALLATION
For cleaning instructions, refer to the blue cleaning guide supplied with your Nexus or
follow the instructions below:
1. Insert cleaning pipe into the centre of the Eazy. Water level in the filter will start to rise.
2. Once the water level to a level just below the overflow, close the inlet valve.
3. Switch water pump off.
4. Insert inlet slide plate.
5. Open air valve to the inner chamber.
6. Close the air valve to the outer chamber.
7. Allow the K1 Micro in the Eazy to agitate for 5 minutes.
8. Open the larger waste valve and wait for the inner chamber to empty.
9. At this stage you may want to hose down any debris from underneath the Eazy.
10. Close the waste valve.
11. Open the air valve to the outer chamber.
12. Close the air valve to the inner chamber.
13. Open Nexus inlet valve.
14. Remove inlet slide plate and then switch pump on.
Steps 2 to 14 should be repeated until the Eazy is clean. It is likely that you will need to
do this 2 to 3 times depending on your pond.
15. When water level rises to the same level as the outer chamber
remove the cleaning pipe.