SERVICE THE EWT G20 CONTROL VALVE
Before Servicing
2. Relieve water pressure in the conditioner by stepping the control into the backwash position
momentarily. Return the control to the In Service position.
3. Unplug electrical cord from outlet.
4.Remove the cover assy
and disconnect the wire
connection.
5.Remove the brine tube,
drain tube, meter cable and
meter tube.
1. Turn off water supply to conditioner using the bypass tool attached on the bypass.
Bypass Tool
Close the inlet
and outlet
Communication
wire conncetions
Drain Tube
Brine Tube
Meter Cable
Meter Tube
2×Screws
2×Clips
6. Remove the clips that
connect control valve and bypass.
7. Disconnect the softener
from the bypass.
8. Remove the valve
from the softener.