The product complies with all the required European product safety, Electromagnetic compatibility and environmental standards. It is fully compliant with the LVD, EMC, RoHS and
Eco design directives.
©Glen Dimplex. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex.
FR: Comme dans le cas de tous les appareils de chauffage portatifs, ce produit convient seulement dans des espaces bien isolés et pour un usage
occasionnel.
EN: As with all portable heating appliances: This product is suitable only for well insulated spaces or occasional use.
08/54785/0 Issue 2
SNOWAIR9HE / SNOWAIR12HE
Manual_Snowair9HE-12HE_2020.indd 1Manual_Snowair9HE-12HE_2020.indd 1 13/11/20 08:1913/11/20 08:19
Question and Answer IconNeed help?

Do you have a question about the EWT SNOWAIR9HE and is the answer not in the manual?

Overview

This document describes the EWT SNOWAIR9HE / SNOWAIR12HE portable air conditioner, which is suitable for well-insulated spaces or occasional use. It complies with European product safety, electromagnetic compatibility, and environmental standards (LVD, EMC, RoHS, and Eco design directives).

Function Description

The EWT SNOWAIR9HE / SNOWAIR12HE is a portable air conditioner designed for cooling, heating, dehumidifying, and fan-only operation. It uses R290 propane gas as a refrigerant.

Operating Modes:

  • Air Conditioning Mode: Ideal for cooling rooms in warm weather. The temperature can be set between 18°C and 32°C (64°F-90°F).
  • Heating Mode: For warming rooms. The temperature can be set between 13°C and 27°C (55°F-81°F). Heating activates only if the selected temperature is higher than the ambient room temperature.
  • Dehumidifier Mode: Reduces humidity in a room, suitable for spring, autumn, damp rooms, or rainy periods. Requires continuous drainage via the drainage pipe.
  • Fan Mode: Circulates air without cooling or heating.

Key Features:

  • LED Screen: Displays current settings and error messages.
  • Control Panel: Touch-sensitive panel on top of the unit for basic function control.
  • Remote Control: Provides full access to all functions, including oscillation, night mode, timer, and temperature unit modification (°C or °F).
  • Oscillation: Vertical oscillation of the air deflector for air flow adjustment (up/down).
  • Night Mode (Sleep Mode): Reduces appliance consumption and screen brightness. In air conditioning mode, the selected temperature increases by 1°C per hour over two hours and then maintains it for six hours before switching off. In dehumidification mode, it operates in the previously selected mode. Not available in fan mode.
  • Timer: Allows delayed start or stop of the appliance (1-24 hours) to optimize energy consumption.
  • Automatic ECO Speed: The appliance automatically adjusts fan speed based on the selected temperature for energy efficiency.
    • In cooling: Fast speed if room temperature is 2°C or more above selected, medium if 1°C above, slow if equal or below.
    • In heating: Fast speed if room temperature is above 25°C, normal if between 23°C and 25°C, slow if below 23°C.
  • Frost Prevention (Anti-gel): Automatically activates in low room temperatures, interrupting normal fan operation and displaying "Lt" on the screen. The appliance will resume normal operation after defrosting.
  • Self-Diagnosis System: Identifies malfunctions and displays error messages (e.g., "PF" for probe failure, "FE" for full tank, "Lt" for low temperature).

Important Technical Specifications

Models: SNOWAIR9HE / SNOWAIR12HE

Electrical Supply: 220-240V~ - 50Hz

Refrigeration Power:

  • SNOWAIR9HE: 9000 Btu/h
  • SNOWAIR12HE: 9000 Btu/h

Heating Power:

  • SNOWAIR9HE: 2300W
  • SNOWAIR12HE: 2900W

Rated Current:

  • SNOWAIR9HE: 4.7A
  • SNOWAIR12HE: 5.7A

EER:

  • SNOWAIR9HE: 3
  • SNOWAIR12HE: 2.61

Dehumidification Capacity:

  • SNOWAIR9HE: 28L/Day
  • SNOWAIR12HE: 36L/Day

Inlet Rated Power:

  • SNOWAIR9HE: 875W
  • SNOWAIR12HE: 1230W

Refrigeration Power (Input):

  • SNOWAIR9HE: 2650W
  • SNOWAIR12HE: 3200W

Water Protection: IPx0

Dimensions (LxWxH): L43.5 x P71.5 x H35 (for both models)

Net Weight:

  • SNOWAIR9HE: 30kg
  • SNOWAIR12HE: 32kg

Refrigerant/Load/GWP: R290 / 0.205kg / 3 (for both models)

CO2 Equivalent: 0.001 tonnes (for both models)

Contains fluorinated greenhouse gases: Yes

Hermetically sealed system: Yes

Air Conditioning Class: Classe A

Max Ventilator Flow (F):

  • SNOWAIR9HE: 330m³/h
  • SNOWAIR12HE: 300m³/h

Sound Power Level (LWA): < 65 dB

Lowest Pressure: 1.2MPa

Maximum Pressure: 2.3MPA

Max. Pressure of Coil: 10MPa

Included Accessories:

  • Exhaust tube connector
  • Expanding exhaust tube
  • Flange outlet connector for exhaust tube
  • Window kit
  • Remote control with battery (CR2025)
  • 1.5m Dehumidifier pipe

Usage Features

Installation:

  • Place on a stable, flat, and robust surface, maintaining at least 45 cm clearance from walls and objects for proper air circulation.
  • For air conditioning mode, the hot air exhaust tube must be connected to a window or opening to vent hot air outside.
  • The window kit is designed for most vertical and horizontal sliding windows. It may require modifications for specific window types and can be secured with screws.
  • Ensure the exhaust tube is unfolded to the minimum required length, without sharp bends or sagging.

Operation:

  • Plug the appliance into an earthed socket to switch to standby mode.
  • Press the On/Off button to turn on the appliance. It will resume the last used function.
  • To switch off, always press the On/Off button and wait a few minutes before unplugging to allow the appliance to perform automatic checks.
  • Temperature unit can be changed between °C and °F by pressing the "M" button on the remote control for 20 seconds while the appliance is in standby mode.

Water Drainage:

  • Manual Drainage: When the internal tank is full (indicated by "FE" on the screen), the appliance stops. Unplug the unit, place a recipient under the drainage cap, remove the cap, drain the water, replace the cap, and restart the unit.
  • Continuous Drainage: Recommended for dehumidification mode. Unplug the unit, remove the drainage cap (some water may escape), connect the 2m drainage pipe, and direct it to a drain, bucket, or sink. Ensure the drainage pipe is not higher than the drainage outlet and has no kinks.

Optimizing Efficiency:

  • Close windows and doors of the room being cooled.
  • For semi-permanent installation, leave a door slightly open (at least 1 cm) for correct ventilation.
  • Protect the room from direct sunlight by closing curtains/blinds.
  • Do not place objects on or block air intake/outlet grills.
  • Ensure no heat sources are in the room.
  • Avoid using in very damp rooms (e.g., laundry rooms) or outdoors.
  • Ensure the appliance is level and lock the wheels if necessary.

Maintenance Features

Cleaning:

  • Always unplug the appliance before cleaning.
  • Clean the surface with a soft, damp cloth. For very dirty surfaces, use a non-corrosive cleaning product.
  • Do not use corrosive detergents, solvents, chemicals, abrasive sponges, scouring pads, or hard brushes.
  • Do not immerse the main body in water.
  • Ensure electrical components do not come into contact with water.

Filter Maintenance:

  • Clean the air inlet filter regularly (monthly recommended, weekly for efficient operation) to prevent dust accumulation and maintain blower function.
  • The evaporator filter can be removed (refer to figures 22-25 in the manual).
  • Use a vacuum cleaner to remove dust from the filter. For very dirty filters, wash them in hot water (not exceeding 40°C / 104°F) and rinse several times. Allow to dry completely before reattaching.

Storage:

  • If not used for a long period, pack it carefully and store it in a dry, ventilated, dust-free area.

End of Season Operations:

  • Completely drain the internal water circuit by removing the cap (refer to figure 21 in the manual) and letting all water flow into a basin. Replace the cap once drained.
  • Clean and dry the filter completely before reinstalling it.

Battery Replacement (Remote Control):

  • The remote control uses a CR2025 3V battery.
  • To replace, insert a safety pin or fine-tipped accessory into the hole on the lid and pull the lid to remove it. Replace the old battery with a new CR2025 battery, then correctly replace the lid.

Safety Information:

  • The appliance contains R290 refrigerant. Do not pierce or burn any components of the cooling circuit.
  • Do not install, operate, or store in a room with a floor area smaller than 4m² (for 10L/12L models) or 7m² (for 14L models).
  • Repairs must be performed by qualified personnel according to manufacturer recommendations.
  • Do not use the appliance if the ambient temperature is below 5°C, as the evaporating coil may ice up.
  • Keep batteries out of reach of children. Seek medical advice if a battery is swallowed.
  • Do not use with extension leads or external switching devices (timers, remote adapters) due to high current consumption and potential overheating/fire risk.
  • Do not cover the appliance or obstruct air inlets/outlets.
  • Keep combustible materials at least 1m away from the air outlet.
  • The water collected in the tank is not suitable for consumption.
  • Regularly clean and empty the water tank (at least every three days) to prevent microbial growth.
  • Wait 3 minutes after the unit stops before restarting to protect the compressor.

Disposal:

  • Dispose of the appliance at an appropriate collection point for WEEE (Waste Electrical and Electronic Equipment) in accordance with European Directive 2012/19/EU.
  • Dispose of used batteries safely.

EWT SNOWAIR9HE Specifications

General IconGeneral
BrandEWT
ModelSNOWAIR9HE
CategoryAir Conditioner
LanguageEnglish

Related product manuals