14
www.exidegroup.com
1 Safety
1.1 General recommendation
Each person given the task of operating or maintaining the battery must have read and understood the instructions.
Only qualified personnel should install the batteries. Knowledge of the contents of the installation and user manual
is a fundamental requirement to protect people from danger, to avoid errors and to operate the system safely and
fault-free.
1.2 Installation / Operation
For the first use, before connecting the battery packs to your equipment fully charge the battery (see
section 2)
The operating conditions given in the product documentation must be observed.
The battery contains a BMS with integrated protection and with the capability to disconnect all battery
power resulting in 0 V and 0 A.
A battery which gets disconnected by BMS during use can lead to immediate loss of function for connected
equipment. Do not install or use in systems where sudden loss of battery power may lead to dangerous
situations or result in malfunction or damage of connected equipment.
The battery is intended for equipment use only. Do not use for starting power (engine crank) or other
similar applications.
If the battery is damaged, deformed, abnormally hot or emits an odor, please cut off the power immediately
and stop using it and contact your local dealer.
1.3 Battery Maintenance
Exide Li-ion charger is recommended to be used. If using any other charger it must respect the charging
requirements of the battery (see section 2).
If the battery voltage is lower than 20V the BMS will disconnect (over discharge protection) and enter sleep
mode to protect the battery from further discharge. Apply charging voltage to wake up BMS and recharge
battery immediately.
The user should verify the condition of all external cables and connections prior to each operation.
Before carrying out any inspection of cables the battery must be disconnected from the application and the
charger.
1.4 Storage conditions
Disconnect all loads from the battery before storage.
In case of long term storage (>6 months), battery must be kept dry and frost free. Storage temperature 15
35 °C, recommended storage humidity 25 ~ 75%,
In case of long term storage (>6 months), maintain battery state of charge (SOC) close to 50% by
maintenance charge every 6 months. 50% SOC correspond to an OCV of ~ 26.4V.
The battery should be recharged at least when the OCV < 25.6V. This correspond to app. 10% SOC.
For seasonal storage (up to 6 months) charge the battery to above 50% SOC before disconnecting.
Suggested storage temperatures up to 1 month -20°C ~ 55°C, up to 3 months -10°C ~ 45°C.
Before taking the battery into use after storage, fully charge the battery.
2 Model range and specifications
2.1 Model range overview
Nominal
Voltage
Rated
Capacity
Rated
Energy
[Wh]
Serial
Parallel
Dimension
L*W*H
[mm]
Weight
[Kg]
25.6 V
25 Ah
640
1
4
196 x 165 x 175
6.0
25.6 V
50 Ah
1280
1
4
318 x 165 x 215
12.5
25.6 V
100 Ah
2560
1
4
505 x 172 x 247
24.0