www.hoyles.com
8mm(maxgap).
Tamper
Tamper
Magnet.Fittodoor
&alignwithcontact
MagneticDoorContact.
Fittodoorframeand
protectfrommoisture
Contact
BkRdYlBl
Dwg60095Iss4Sept14
Lo
Lo
On
On On On On
On
On On On On
Hi
Hi
Off
Off Off Off Off
Off
Off Off Off Off
TONE
TONE
DELAY
DELAY DELAY DELAY DELAY
CHIME
CHIME CHIME CHIME CHIME
KeyReset
ie2mins+
90s
10s
1s
Jumperlinksshownin
factorydefaultpositions
Movejumpertoselect
lowpitchtone
Movejumpertoselect15s
alarmdelay(DOTL)
Movejumpertoselect
doorchimefacility
COM
NC
NO
A1
A2
T1
T2
-ve
+ve
K1K2 To1To2
Voltfreeauxiliaryrelay
contacts.
Changeonalarmcondition
EX105&Ex106versions
6x AA batteries
(Ex104versions)
Do power
from12vdc.
Thiswillresult
indamage.
NOT
Keyswitch
12vdcPowerInEx105
or
12vdcPowerOut150maEX106
EXITGUARDEX104,EX105&EX106 24hourDoorAlarm
Tamper
Input
Alarm
Input
Start
Key
90s
10s
1s
Alarm
Chime
or
Alarm
Chime[1]
Auto
orKey
Reset
Delayed
orInstant
Alarm
Warning
atstartof
delay
Autoreset
Delayed
Instant[4]
Yes
No
BasicCHIMEfaciltyrepeatsat15secondintervals
AutoResettimecanbeadjustedbetween1sec
and90secs.Beyond90secsitbecomesKeyReset
Turnpotfully
clockwiseto
invokeKeyReset
ieFactorydefault
Setjumpersfordesiredoperation
Note:Therearenoprogramming
optionsfortamperfacilities.
Controlwith
Keyswitch
Factory
Default
Options
TheEX100seriesEXITGUARDprovidesasimpletooperatesolutionforthe24hourprotectionoffireexitand
otherdoors. A numberofoptionsareavailablethatcanbesetupattheinstallationstage. Thefollowing
featuresarestandardtoallEX100seriesEXITGUARDs:
BasicChimerepeatingat15secintervals[1]
AutoResetadjustable1secto90secs[2]
KeyswitchReset[3]
Instant Alarm[4]
Reducedalarmafter2minutesifnotreset
Delaybeforealarmwithoutpre-warn[5]
Delaybeforealarmwithpre-warn[6]
Lowleveltamperfor2minsthenevery5mins
Tamperomit.
Lowbatterywarningonset&at5minintervals
Hi&Lolevelalarmtones
LEDstatusindicator
Doublebleepforset,singlebleepforun-set.
Passthrough/safesetfacility.
IsolatealarmbyturningKeyswitchtooffposition
Poweredfrom6x AA batteries(supplied)EX104orfroma
12vdcintruderalarmsupplyEx105
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
[1][5][6]
[2]
[3]
RESET
CONTROL
Theexactpositionformaximumresettime
(90secs)isapprox.2o'clock.Todetermine
thispositionexactlyensurethatthedoor
contactandthetamperlooparebothopen.
ThekeyswitchshouldbeintheO(Off)
position.ApplypowerandswitchtotheI
(On)positionwithin3seconds.Thesounder
willgiveableepfollowedbyfourrapidbleeps
Turnthepotentiometerslowlyandobserve
thefollowing:
AtKeyResetaChime&noLED
AtMaxResetaBarp&noLed
BelowMaxResetSilenceandsteadyLED
ToneSelectdoes
notaffectanyother
programming
16vac
from
transformer
F
U
S
E
NEL
220/240vac
EX106only
NC
COM
NO
Blue
Yellow
White
EX105KMisfitted
withauxiliaryvolt
freeterminalsfor
remotesignalling
ofSet/Unset