EasyManua.ls Logo

EXITGUARD EX104 User Manual

Default Icon
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
www.hoyles.com
8mm(maxgap).
Tamper
Tamper
Magnet.Fittodoor
&alignwithcontact
MagneticDoorContact.
Fittodoorframeand
protectfrommoisture
Contact
BkRdYlBl
Dwg60095Iss4Sept14
Lo
Lo
On
On On On On
On
On On On On
Hi
Hi
Off
Off Off Off Off
Off
Off Off Off Off
TONE
TONE
DELAY
DELAY DELAY DELAY DELAY
CHIME
CHIME CHIME CHIME CHIME
KeyReset
ie2mins+
90s
10s
1s
Jumperlinksshownin
factorydefaultpositions
Movejumpertoselect
lowpitchtone
Movejumpertoselect15s
alarmdelay(DOTL)
Movejumpertoselect
doorchimefacility
COM
NC
NO
A1
A2
T1
T2
-ve
+ve
K1K2 To1To2
Voltfreeauxiliaryrelay
contacts.
Changeonalarmcondition
EX105&Ex106versions
6x AA batteries
(Ex104versions)
Do power
from12vdc.
Thiswillresult
indamage.
NOT
Keyswitch
12vdcPowerInEx105
or
12vdcPowerOut150maEX106
EXITGUARDEX104,EX105&EX106 24hourDoorAlarm
Tamper
Input
Alarm
Input
Start
Key
90s
10s
1s
Alarm
Chime
or
Alarm
Chime[1]
Auto
orKey
Reset
Delayed
orInstant
Alarm
Warning
atstartof
delay
Autoreset
Delayed
Instant[4]
Yes
No
BasicCHIMEfaciltyrepeatsat15secondintervals
AutoResettimecanbeadjustedbetween1sec
and90secs.Beyond90secsitbecomesKeyReset
Turnpotfully
clockwiseto
invokeKeyReset
ieFactorydefault
Setjumpersfordesiredoperation
Note:Therearenoprogramming
optionsfortamperfacilities.
Controlwith
Keyswitch
Factory
Default
Options
TheEX100seriesEXITGUARDprovidesasimpletooperatesolutionforthe24hourprotectionoffireexitand
otherdoors. A numberofoptionsareavailablethatcanbesetupattheinstallationstage. Thefollowing
featuresarestandardtoallEX100seriesEXITGUARDs:
BasicChimerepeatingat15secintervals[1]
AutoResetadjustable1secto90secs[2]
KeyswitchReset[3]
Instant Alarm[4]
Reducedalarmafter2minutesifnotreset
Delaybeforealarmwithoutpre-warn[5]
Delaybeforealarmwithpre-warn[6]
Lowleveltamperfor2minsthenevery5mins
Tamperomit.
Lowbatterywarningonset&at5minintervals
Hi&Lolevelalarmtones
LEDstatusindicator
Doublebleepforset,singlebleepforun-set.
Passthrough/safesetfacility.
IsolatealarmbyturningKeyswitchtooffposition
Poweredfrom6x AA batteries(supplied)EX104orfroma
12vdcintruderalarmsupplyEx105
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
[1][5][6]
[2]
[3]
RESET
CONTROL
Theexactpositionformaximumresettime
(90secs)isapprox.2o'clock.Todetermine
thispositionexactlyensurethatthedoor
contactandthetamperlooparebothopen.
ThekeyswitchshouldbeintheO(Off)
position.ApplypowerandswitchtotheI
(On)positionwithin3seconds.Thesounder
willgiveableepfollowedbyfourrapidbleeps
Turnthepotentiometerslowlyandobserve
thefollowing:
AtKeyResetaChime&noLED
AtMaxResetaBarp&noLed
BelowMaxResetSilenceandsteadyLED
ToneSelectdoes
notaffectanyother
programming
16vac
from
transformer
F
U
S
E
NEL
220/240vac
EX106only
NC
COM
NO
Blue
Yellow
White
EX105KMisfitted
withauxiliaryvolt
freeterminalsfor
remotesignalling
ofSet/Unset
Question and Answer IconNeed help?

Do you have a question about the EXITGUARD EX104 and is the answer not in the manual?

EXITGUARD EX104 Specifications

General IconGeneral
BrandEXITGUARD
ModelEX104
CategorySecurity System
LanguageEnglish

Summary

EXITGUARD EX104, EX105 & EX106 24 hour Door Alarm

Standard Features

Lists standard features including chime, auto reset, keyswitch reset, instant alarm, low battery warning, and tamper functions.

Wiring and Connections

Covers magnetic door contact, tamper loop, power input (battery/12VDC), auxiliary relay contacts, and mains connection.

Jumper Settings for Operation

Explains jumper configurations for selecting tone pitch, alarm delay (DOTL), and enabling the door chime facility.

Configuration Options

Details options for Tone Select, Chime, Auto Reset time adjustment, Keyswitch Reset, and Delayed or Instant Alarm settings.