8mm(maxgap).
Tamper
Tamper
Magnet.Fittodoor
&alignwithcontact
MagneticDoorContact.
Fittodoorframeand
protectfrommoisture
Contact
BkRdYlBl
Dwg60095Iss4Sept14
Lo
Lo
On
On On On On
On
On On On On
Hi
Hi
Off
Off Off Off Off
Off
Off Off Off Off
TONE
TONE
DELAY
DELAY DELAY DELAY DELAY
CHIME
CHIME CHIME CHIME CHIME
KeyReset
ie2mins+
90s
10s
1s
Jumperlinksshownin
factorydefaultpositions
Movejumpertoselect
lowpitchtone
Movejumpertoselect15s
alarmdelay(DOTL)
Movejumpertoselect
doorchimefacility
COM
NC
NO
A1
A2
T1
T2
-ve
+ve
K1K2 To1To2
Voltfreeauxiliaryrelay
contacts.
Changeonalarmcondition
EX105&Ex106versions
6x AA batteries
(Ex104versions)
Do power
from12vdc.
Thiswillresult
indamage.
NOT
Keyswitch
12vdcPowerInEx105
or
12vdcPowerOut150maEX106
EXITGUARDEX104,EX105&EX106 24hourDoorAlarm
Tamper
Input
Alarm
Input
Start
Key
90s
10s
1s
Alarm
Chime
or
Alarm
Chime[1]
Auto
orKey
Reset
Delayed
orInstant
Alarm
Warning
atstartof
delay
Autoreset
Delayed
Instant[4]
Yes
No
BasicCHIMEfaciltyrepeatsat15secondintervals
AutoResettimecanbeadjustedbetween1sec
and90secs.Beyond90secsitbecomesKeyReset
Turnpotfully
clockwiseto
invokeKeyReset
ieFactorydefault
Setjumpersfordesiredoperation
Note:Therearenoprogramming
optionsfortamperfacilities.
Controlwith
Keyswitch
Factory
Default
Options
TheEX100seriesEXITGUARDprovidesasimpletooperatesolutionforthe24hourprotectionoffireexitand
otherdoors. A numberofoptionsareavailablethatcanbesetupattheinstallationstage. Thefollowing
featuresarestandardtoallEX100seriesEXITGUARDs:
BasicChimerepeatingat15secintervals[1]
AutoResetadjustable1secto90secs[2]
KeyswitchReset[3]
Instant Alarm[4]
Reducedalarmafter2minutesifnotreset
Delaybeforealarmwithoutpre-warn[5]
Delaybeforealarmwithpre-warn[6]
Lowleveltamperfor2minsthenevery5mins
Tamperomit.
Lowbatterywarningonset&at5minintervals
Hi&Lolevelalarmtones
LEDstatusindicator
Doublebleepforset,singlebleepforun-set.
Passthrough/safesetfacility.
IsolatealarmbyturningKeyswitchtooffposition
Poweredfrom6x AA batteries(supplied)EX104orfroma
12vdcintruderalarmsupplyEx105
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
[1][5][6]
[2]
[3]
RESET
CONTROL
Theexactpositionformaximumresettime
(90secs)isapprox.2o'clock.Todetermine
thispositionexactlyensurethatthedoor
contactandthetamperlooparebothopen.
ThekeyswitchshouldbeintheO(Off)
position.ApplypowerandswitchtotheI
(On)positionwithin3seconds.Thesounder
willgiveableepfollowedbyfourrapidbleeps
Turnthepotentiometerslowlyandobserve
thefollowing:
AtKeyResetaChime&noLED
AtMaxResetaBarp&noLed
BelowMaxResetSilenceandsteadyLED
ToneSelectdoes
notaffectanyother
programming
16vac
from
transformer
F
U
S
E
NEL
220/240vac
EX106only
NC
COM
NO
Blue
Yellow
White
EX105KMisfitted
withauxiliaryvolt
freeterminalsfor
remotesignalling
ofSet/Unset