20
20. LIMITATIONS
The connection signal can be blocked by carbon and metal. Operation on carbon or metal boats will require
the OLAS N2K hub to be mounted externally.
SOUND AND LIGHT INDICATIONS
OPERATION ACTION / REACTION
Turning ON
Control switch: Green
Hub: Low red
Buzzer: ON
No OLAS transmitters in range
Control switch: Green / Red alternating
Buzzer: 8+ beeps incremental every minute up to 30 minutes
New transmitter tracked
Control switch: Red double ash
Buzzer: Double Beep
Checking logged OLAS transmitters
Control switch: Red ash per tracked tag
Buzzer: Single beep per tracked tag
Alert delay warning
Control switch: Green
Buzzer: Rapid beep
MOB Alert
Control switch: Red constant
Hub: High red constant
Buzzer: Beep every second
System paused
Control switch: Red 3 seconds, off 3 seconds continuous
Buzzer: Beep every 6 seconds (if not muted)
Low battery alert <20%
Control switch: Red ash every 10 seconds
Hub: Red ash every 10 seconds
SPECIFICATION
Power/Current excluding external accessories 10-32V/13~17mA
Recommended maximum vessel length 50ft
Tracked Transmitters up to 25
Weight TBC
Size 92 x 90 x 38 mm
LED output 55lm
Buzzer output 85db
EXPUG31.indd 20EXPUG31.indd 20 15/05/2023 12:1815/05/2023 12:18