EZ Answer
of digits to be entered. Where a variable length entry is
permitted, if less than the maximum number of digits permitted
for that program are entered, the # key is used to terminate the
entry sequence.
For the fixed length entry programs, the unit will start
processing the entered digits as soon as all the digits are entered.
The # key is not to be used for terminating the entry
sequence for these programs.
If no digits are input for 60 seconds, the unit will time-out and
exit from the programming mode.
On successful completion of a program, the old values will be
overwritten with the new values in the unit's non-volatile
memory and will come into effect after exiting from the
programming mode. The unit may take about 1 second to write
the values in the non-volatile memory. If more than 1 digit is
entered during this period, it will lead to an error or unexpected
consequences.
Hence, if you are using a butt set to program the unit, it is
advisable to wait for at least 1 second before continuing with the
next program.
The values that are currently programmed in the system may
also be ascertained by `listening' to the values prompted by the
system. The # key is not prompted since it is used to terminate
an entry.
After the programming is over and the user exits the
programming mode by pressing ###, the unit will start
playing the main greeting and the user can now transfer
to another extension or test the parameters that were
just programmed.
13