EZ Answer
returned, the appropriate message is played back to the calling
party.
The ring signal has a very specific cadence and any response not
matching the ringing sequence of 1 second ring - 3 second
silence will be taken as answered and the caller will be connected
to that extension.
Enter 206 n where n = 3 to 9 rings
For all other digits, the unit will prompt the message “This
entry is invalid”.
Default value = 3 Length of entry = fixed 1 digit
Program # 246:
To listen to the currently programmed value for the Number of
rings for No Answer -
You will hear: “ Two Four Six (0.6 sec silence) Three”
Program # 207:
To enter the list of Invalid Extensions -
Under this program, the extensions are entered one by one.
After entering the program number, enter the first extension to
be placed in the list-of-invalid-extensions. The extensions must
be of a fixed length as programmed under Program No. 204. The
unit will check for validity and store that extension in the
memory and then give 2 short beeps to indicate that you can
now enter the next extension.
An all-0 extension is invalid and a * in the extension is invalid. If
an invalid extension is entered, the unit will prompt “This entry
is invalid” and return to the “Enter Program number”
30