Gather essential cleaning items including the f'REAL! Sanitizing Cup and approved sanitizer.
Thoroughly wash hands and prepare the sanitizing cup with dishwashing liquid and hot water.
Open the blender front door to access the blending chamber; power must remain on.
Clean all parts of the blender thoroughly using the f'REAL! Brush and sanitizing solution.
Rinse the sanitizing cup and prepare the sanitizing solution with the correct sanitizer concentration.
Place the sanitizing cup and initiate the 2-minute sanitize cycle using specific button presses.
Apply sanitizing solution to the underside and top of the metal cup lid after the cycle.
Dispose of remaining sanitizing solution into the drain and rinse all equipment thoroughly.
Do not use the f'REAL! Brush or Cup on other equipment; replace the brush regularly.
Use provided test strips to confirm iodophor sanitizing solution concentration (12.5-25 ppm).
The f'REAL! Blender is a commercial beverage preparation device designed for blending various f'REAL! products, likely milkshakes or similar frozen beverages. Its primary function is to blend pre-packaged f'REAL! cups into a ready-to-drink consistency.
The blender operates with a front-loading mechanism, where pre-packaged f'REAL! cups are placed into a cup holder within the blending chamber. The blending process is initiated by selecting desired options, indicated by "Less Thick" and "More Thick" buttons, suggesting customizable consistency. The device is designed for continuous operation, as users are instructed not to turn off the blender power during cleaning and sanitizing to ensure it recognizes that maintenance has been performed.
The f'REAL! Blender emphasizes rigorous daily cleaning and sanitizing protocols, which must be performed every 24 hours. The process is detailed and requires specific f'REAL! branded accessories: a f'REAL! Sanitizing Cup, a f'REAL! Brush, dishwashing liquid, and BTF Iodophor Sanitizer (or an approved quaternary sanitizer).
The cleaning process involves:
The sanitizing process follows the cleaning:
The blender uses a metal cup lid, a blending disc and slider, a blending shaft, gray plastic blending chamber walls, a front door liner, and clear plastic flip-up doors. The sanitizer concentration for Iodophor is specified at 12.5 ppm to 25 ppm, confirmed using test strips provided in a vial with sanitizer kits. Quaternary sanitizers, if used, should be diluted to 200 ppm.