10
50 65
72
cm
100
120
REMOTE CONTROL ADJUSTMENTS (OPTIONAL)
MIN. DETECTED
OBJECT SIZE
approximate values
DETECTION TRAJECTORY
MAX. PRESENCE TIME
During detection, the sensor automatically switches from motion to presence detection for a
given presence time. Once the object has left the detection field, the presence time is aborted.
off
opening field
opening field
opening field
BIDIRECTIONAL
bidirectional detection
approaching and going
away
400% CENTER
unidirectional detection
only approaching
in any direction
200% CENTER
unidirectional detection
only approaching
towards the barrier/gate
100% CENTER
unidirectional detection
only approaching
within width of barrier/gate
50% CENTER
unidirectional detection
only approaching
towards central zone of
barrier/gate
25% CENTER
unidirectional detection
only approaching
towards centre of barrier/
gate
100% RIGHT
unidirectional detection
only approaching
towards right side
100% LEFT
unidirectional detection
only approaching
towards left side
5 s 10 s 30 s
1 min
2 min 5 min 10 min
2 h infinite
off