5
1
1
2
3
4
5
6
l
min
(mm)
h
min
(mm)
50 240 52
100 360 59
150 480 66
200 600 73
l
MOUNTING
Use the LBA mounting support
for installation on the pole.
Position the bracket and fasten
the 4 screws firmly in order to
avoid vibrations.
Close the protection cover and
fasten it firmly.
Turn the sensor until the two
triangles are face to face.
Position the housing on the
bracket.
Open the protection cover, plug
the connector and position the
cable in the slit.
Keep the front face of the sensor free! Do not cover with glass or plastic.
40 cm
(recommended)
d (mm)
distance between
laser and opening
side view
front view