Pellets Stove
21
2121
21
stove fitter to check the chimney
from the stove outlet to the chimney
pot). Have it cleaned immediately.
Clean the stove inside (see
Maintenance)
Pellets can burn thanks to the
chimney flue depression without the
aspirator. Have it replaced
immediately (cod. Com0236) as it
can be bad for your health. Call a
specialised technician.
The exchanger fan
keeps working when
the stove is cold
Temperature fumes feeler is faulty
Electronic card is faulty
Replace the fumes feeler, cod
Com0239. Call a specialised
technician
Replace the card, cod Com0231.
Call a specialised technician
Hash around the stove Faulty or damaged doors strips
Fumes pipe tubes are not airtight
Replace the strips cod.
Com0244+Com0245
Seal immediately the pipe fitting
(with high temperature silicone)
and/or replace the pipes with new
ones. Fumes pipes that aren’t
airtight can be dangerous for your
health. Call an expert stove fitter.
The stove switches off.
Alarm displayed “AlAr
no rEtE”
Plug accidentally unplugged
Temporary power failure
Faulty electronic card
Verify the plug is plugged in
Verify the power failure and start the
stove again
Replace the card, cod Com0231.
Call a specialised technician
The stove is in steady
condition, the display
shows: “RiS”
Environment temperature reached
Fumes outlet temperature reached
The stove works at minimum rate: no
problem
The stove works at minimum rate: no
problem
When working normally
the stove display
shows “Stop Fire”
Cleaning grate The stove goes to minimum and
extraction ventilation to maximum:
no problem
The stove switches off.
Alarm displayed: “AlAr
dEP”
The door isn’t closed
The waste outlet is obstructed
Fumes extractor is damaged
Rubber connection is obstructed
Pressure switch is faulty
Electronic card is faulty
Excessive chimney length
Bad weather conditions
Closed the door properly and check
the door strips are in good
conditions otherwise replace them
cod. Com0244+Com0245
The fumes waste chimney is partially
or totally obstructed (call an expert
stove fitter to check the chimney
from the stove outlet to the chimney
pot). Have it cleaned immediately.
Pellets can burn thanks to the
chimney flue depression without the
aspirator. Have it replaced
immediately (cod. Com0236) as it
can be bad for your health. Call a
specialised technician.
Take the silicone pipe off and with
the help of a pointed tool clean the
bodying hole. Replace the pipe if
necessary cod. Com0401
Replace the pressure switch, cod
Com0233. Call a s
p
ecialised