IF THERE IS A PROBLEM
IF THERE IS A PROBLEMIF THERE IS A PROBLEM
IF THERE IS A PROBLEM
Problem
ProblemProblem
Problem
Cause
CauseCause
Cause
Solution
SolutionSolution
Solution
The control panel
doesn’t start
The stove hasn’t got electrical input
Card protection fuse is burned
Control panel is faulty
Flat cable is faulty
Electronic card is faulty
Verify if the plug is connected
Replace the fuse. Call a specialised
technician
Replace the control panel
cod.Com0241. Call a specialised
technician
Replace the flat cable
cod.Com0240. Call a specialised
technician
Replace the electronic card
cod.Com0231. Call a specialised
technician
The stove doesn’t start.
Alarm displayed: “AlAr
no FirE”
The tank is empty
The brazier isn’t cleaned
The feeler hasn’t detected the
minimum threshold to start
Starting plug is faulty
Outside temperature is too cold
Pellets are wet
Thermal feeler is blocked
Electronic card is faulty
Fill the tank
Clean the brazier (see Maintenance)
Empty the brazier and start again, if
the problem continues call a
specialised technician
Replace the plug, cod Com0234.
Call a specialised technician
Restart the stove
Pellets must be stored in a dry room.
Verify
Replace the feeler, cod Com0139.
Call a specialised technician
Replace the card, cod Com0231.
Call a specialised technician
Pellets don’t get to the
fire box
The tank is empty
Cochlea is blocked by a strange object
(ex. Nails)
Cochlea gear motor is damaged
Verify if there is an alarm activated on
display (ex. AlAr dEP., AlAr Sic…..)
Fill the tank
Unplug the plug, move the inside
hand protection of the tank, empty
the tank, clean the cochlea e start
again
Replace the gear motor, cod
Com0232. Call a specialised
technician
Call a specialised technician to
check the stove and detect the
problem
The fire goes out and
the stove stops
The tank is empty
Cochlea is blocked by a strange object
(ex. Nails)
Pellets aren’t of good quality
The phase 1 parameter set in the
electronic card is too low
Verify if there is an alarm activated on
display (ex. AlAr dEP, AlAr Sic…..)
Fill the tank
Unplug the plug, move the inside
hand protection of the tank, empty
the tank, clean the cochlea e start
again
Try different types of pellets
The pellets supply must be regulated
by a specialised technician
Call a specialised technician to
check the stove and detect the
problem
The fire has a weak
and orange flame,
pellets don’t burn
correctly and the glass
gets black
The air for combustion isn’t enough
The waste pipe is blocked
The stove is obstructed
Fumes extractor is damaged
Check the following: possible
obstructions of the air inlet on the
back of the stove: brazier grid holes
obstructed and/or brazier box with
too much hash: exchanger pipes too
dirty; clean the extractor blades and
its scroll (see Maintenance)
Exhaust chimney is partially or
totall
y
obstructed
(
call an ex
p
ert