Class10B
AC53a 3.5-12:75-5
Class10
AC53a 3-23:75-5
Class20
AC53a 4-19:75-5
Class30
AC53a 4-29:75-5
Class10B
AC53b 3.5-12:708
Class10
AC53b 3-23:697
Class20
AC53b 4-19:701
Class30
AC53b 4-29:691
3A 3A 3A 3A 5A 4A 3A 3A
6A 6A 6A 6A 9A 9A 7A 6A
8A 8A 8A 7A 12A 12A 9A 8A
13A 13A 10A 9A 18A 19A 12A 11A
19A 19A 18A 17A 23A 28A 21A 20A
23A 23A 22A 21A 31A 34A 26A 24A
27A 27A 25A 24A 35A 40A 30A 29A
33A 33A 31A 30A 45A 49A 37A 35A
35A 35A 30A 28A 46A 43A 33A 31A
41A 44A 35A 33A 47A 51A 39A 37A
44A 46A 44A 43A 56A 72A 55A 51A
55A 55A 55A 54A 85A 89A 69A 64A
70A 70A 59A 58A 85A 84A 63A 61A
77A 85A 66A 64A 86A 92A 70A 67A
88A 98A 75A 73A 94A 105A 80A 77A
98A 108A 83A 81A 107A 117A 89A 85A
116A 128A 99A 96A 126A 139A 106A 101A
132A 135A 112A 106A 146A 159A 122A 115A
154A 166A 131A 124A 171A 186A 143A 134A
179A 190A 151A 142A 203A 215A 167A 156A
Continuous/Optimising Externally Bypassed
-1 -2 -3 -4 -5 -6 -7 -8
Class10B
AC53a 3.5-12:60-3
Class10
AC53a 3-23:60-3
Class20
AC53a 4-19:60-3
Class30
AC53a 4-29:60-3
Class10B
AC53b 3.5-12:1188
Class10
AC53b 3-23:1177
Class20
AC53b 4-19:1181
Class30
AC53b 4-29:1171
209A 225A 174A 164A 218A 232A 178A 167A
243A 261A 202A 190A 253A 270A 208A 195A
314A 314A 242A 222A 330A 322A 250A 230A
350A 320A 258A 235A 360A 344A 272A 242A
370A 350A 274A 248A 390A 364A 288A 256A
440A 412A 325A 295A 460A 433A 342A 305A
500A 500A 445A 420A 520A 515A 460A 430A
540A 540A 460A 425A 560A 562A 480A 435A
630A 630A 480A 430A 662A 655A 500A 442A
780A 750A 600A 530A 817A 780A 628A 543A
795A 780A 615A 545A 825A 800A 640A 560A
850A 850A 724A 650A 875A 895A 754A 665A
950A 950A 810A 727A 1000A 1000A 842A 744A
1060A 1060A 904A 812A 1100A 1115A 940A 830A
1150A 1150A 980A 880A 1209A 1210A 1020A 900A
1150A 1150A 980A 880A 1209A 1210A 1020A 900A
1320A 1320A 1050A 930A 1360A 1360A 1080A 950A
1400A 1400A 1110A 950A 1400A 1430A 1160A 970A
1550A 1520A 1230A 1050A 1560A 1580A 1280A 1075A
1850A 1750A 1460A 1190A 1998A 1810A 1520A 1225A
Continuous/Optimising Externally Bypassed
-1
-2 -3 -4 -5 -6 -7 -8
XFE No.
XFE No.
The owner, installer and user is responsible for the correct installation and use of the XFE and must ensure that
only qualified personnel install the XFE and that the installation, operation and maintenance of the unit complies
with the relevant Codes of Practice, Regulations and Statutory Requirements. The Manufacturer or his agent do
not assume any liability, expressed or implied, for any consequence resulting from inappropriate, negligent or
incorrect installation, application, use or adjustment of the product or circuit design, or from the mismatch of the
unit to a motor. To prevent an electrical shock hazard the XFE must be connected to a safety earth. The unit is not
designed for use in hazardous areas. Use in such an area may invalidate the hazardous area certification.
XFE Current Ratings
Index Ratings
In line with the stated IEC starting duties, all XFE 100 series have an enforced off period of 2 minutes, likewise all
XFE 200 and XFE 300 series have an enforced off period of 7 minutes set as standard. During this period the
display indicates “Stopped.Cooling”, and the XFE will not respond to a start signal.
XFE202
XFE204
XFE206
XFE208
XFE210
XFE212
XFE302
XFE304
XFE306
XFE308
XFE310
XFE312
XFE314
XFE316
XFE318
XFE319
XFE320
XFE322
XFE324
XFE326
XFE102
XFE104
XFE106
XFE108
XFE110
XFE112
XFE114
XFE116
XFE118
XFE120
XFE122
XFE124
XFE126
XFE128
XFE130
XFE132
XFE134
XFE136
XFE138
XFE140