EasyManua.ls Logo

FAIRLINE MAC2300C - General Safety Warnings

FAIRLINE MAC2300C
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
t MOBILE AIR-CONDITIONER
MAC2300C
Dear Customer,
Congratulations on your purchase of this FAIRLINE product.
Please take a few minutes before starting operation of the appliance and read
the following operating instructions.
Many thanks.
1. Description
This air conditioner is designed to cool down or dehumidify indoor rooms.
The appliance is not intended for any commercial or industrial use. Do not use
it for other purposes. Any other use might lead to damage of the appliance or
personal injury.
For detailed information see overview illustration.
1. Control panel
a. Display
b. Unit indicator °F / °C
c Fan speed indicators HIGH /
LOW
d. Fan speed button FAN
e. Timer program button TIMER
with indicators
f. Increase button
g. On/standby button
with
indicator
h. Decrease button
i. Sleep mode button SLEEP
with indicator
j. Mode selection button MODE
k. Mode indicators
AUTO / FAN / DRY /
COOL
2. Louvre blade
3. Remote control receiver
4. Recessed handle
5. Upper drain outlet
6. Castor
7. Air filter
8. Air exhaust
9. Air inlet
10. Power cord tie
11. Power cord with plug
12. Lower drain outlet
13. Remote control
a. Remote control emitter
b. Display with function
indicators
c. Pre-programmed button
SHORT CUT
d. Timer button TIMER ON
e. Timer button TIMER OFF
f. Display/indicator ON/OFF
button LED
g. Battery compartment with lid
h. Sleep mode button SLEEP
i. Temperature up/down
j. Fan speed button FAN
k. Mode selection button MODE
l. Power switch ON/OFF
14. Exhaust hose
15. Wall adaptor
16. Wall connector
17. Exhaust connector
18. Wall plug (x4)
19. Screw (x4)
20. Drainage hose
21. Battery (LR03/AAA) (x2)
2. Safety warnings
IMPORTANT SAFETY INSTRUCTIONS!
READ CAREFULLY AND KEEP FOR FUTURE
REFERENCE! PAY PARTICULAR ATTENTION
TO ALL FIGURES ON ILLUSTRATION PAGE
Read this instruction manual carefully
before using the appliance. Familiarise
yourself with the operation, adjustments
and functions of switches. Internalise
and follow the safety and operation
instructions in order to avoid possible
risks and hazards.
Remove all packaging materials.
WARNING - DANGER OF
SUFFOCATION!
Packaging materials are not toys.
Children should not play with the
packaging materials, as they pose a risk
of swallowing and suffocation!
WARNING!
Switch the appliance off and disconnect
it from the power supply before
replacing attachments, cleaning work
and when not in use.
WARNING - RISK OF ELECTRIC
SHOCK!
Protect the electrical parts against
moisture. Do not immerse such parts in
water or other liquids to avoid electrical
shock. Never hold the appliance under
running water. Pay attention to the
instructions for cleaning and care.
Do not operate the appliance with wet
hands or while standing on a wet floor.
Do not touch the power plug with wet
hands.
This appliance is classified as protection
class I and must be connected to a
protective ground.
Only use in dry indoor rooms.
Dry
Damp
Air conditioner warnings
1. This appliance can be used by children
aged from 8 years and above and persons
with reduced physical, sensory or mental
capabilities or lack of experience and
knowledge if they have been given
supervision or instruction concerning use of
the appliance in a safe way and understand
the hazards involved.
2. Children shall not play with the appliance.
3. Cleaning and user maintenance shall not be
made by children without supervision.
4. If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order
to avoid a hazard.
5. Ensure the minimum surrounding distance
around the appliance stated in the
technical data and always provide sufficient
ventilation.
16
171514
201918
21
ON/OFF
SHORT
CUT
TIMER
ON
TIMER
OFF
MODE
FAN
TEMP
SLEEP LED
20
FAN
Set Temp.
Auto
Cool
Dry
Heat
Fan
Auto
Timer On Timer Off
13 13a
13b
13c
13d
13e
13f
13g
13h
13j
13k
13l
13i
20
FAN
Set Temp.
Auto
Cool
Dry
Heat
Fan
Auto
Timer On Timer Off
2300 W
65 dB
1
TEMP
20
FAN
Set Temp.
Auto
Cool
Dry
Heat
Fan
Auto
Timer OnTimer Off
2
SHOP
3
4
5
2.
1.
6 7
“click”
8
30 cm
30 cm
9
max 120 cm
min 30 cm
10
11
12
2.
1.
13
MIN
2 h
&1
)$1
&1
83
*5((125<*
:+,7(25%/8(
%/$&.25%52:1
32:(5
6:
&1
%/$&.
M
~
%52:1
%/8(
&1
',63/$<%2$5'
33
33
1
$0%,(176(1625
(9$325$7256(1625
&1
<*
EL
SU
5<
4
3
02725
~
3
%/$&.
M
<*
5('
&$3
&2035(6625
%/$&.
5('
M
~
<*
%/8(
%/8(
&203
0$,1%2$5'
&1
)$1
83
*5((125<*
:+,7(25%/8(
%/$&.25%52:1
32:(5
6:
&1
%/$&.
M
~
%52:1
%/8(
&1
',63/$<%2$5'
33
33
1
$0%,(176(1625
(9$325$7256(1625
&1
<*
EL
SU
5<
4
3
02725
~
3
%/$&.
M
<*
5('
&$3
&2035(6625
%/$&.
5('
M
~
<*
%/8(
%/8(
&203
&1
)$1
&1
83
*5((125<*
:+,7(25%/8(
%/$&.25%52:1
32:(5
6:
&1
%/$&.
M
~
%52:1
%/8(
&1
',63/$<%2$5'
33
33
1
$0%,(176(1625
(9$325$7256(1625
&1
<*
7
EL
SU
5<
4
3
02725
~
3
%/$&.
M
<*
5('
&$3
&2035(6625
%/$&.
5('
M
~
<*
%/8(
%/8(
&203
&1
&1
&1
32:(5%2$5'
237,21$/
This symbol indicates the element is
optional,the actual shape shall prevail
237,21$/
GB
1
IM_MAC2300C_A4_161101.indb 2 1/11/16 11:27 AM