EasyManua.ls Logo

Faller 180633 - Rectifier Functionality and Technical Data; Rectifier Functionality; Component Switching Methods; Technical Data Specifications

Faller 180633
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
IMPORTANT: It is also possible to connect more components than specified above,
if the sum of the »required power« of the »ACTIVE components« does not exceed 2500 mA.
e.g.: 20 stop points, of which 10 pcs. are »ACTIVE« 10 x 138 mA = 1380 mA
20 branches, electrical, of which 8 pcs. are »ACTIVE« 8 x 138 mA = 1104 mA
SUM = 2484 mA
20 2 LED bar spotlights 40 x 60 mA = 2400 mA
There is a remaining amount of 516 mA for components to be activated by »buttons«.
These are: 3 pcs. of stop points or
3 pcs. of branches or
2 pcs. - one stop point and one branch
Application: Manual control of the FALLER Car System
Functioning:
A Rectifier It transforms AC into DC.
The rectifier is connected to a transformer 12 -16 V AC,
e.g. FALLER transformer Art. No. 180641.
Switching of the individual components by:
Art. No.: 161675 Stop point Switch
Art. No.: 161677 Branch, electrical Button (without series resistor) or
Switch (with 47-Ohm series resistor)
Art. No.: 161676 Branch Button
Art. No.: 161674 Parking lot Button
Art. No.: 16168 .. Magnet enable coil Button
B Connection diagram Various examples for FALLER Car System components.
Button T ... Instantaneous switch Voltage only as long as button is operated.
Switch S ... Continuous - ON / OFF Voltage is permanently ON / OFF.
Technical data:
180633 rectifier Input voltage 12 - 16 V AC
Current input up to 3000 mA AC (5 - 10 minutes)
Output voltage at 12 VAC approx. 16.9 V DC
(unloaded) at 16 VAC approx. 22.6 V DC
Max. continuous current loading 2500 mA DC