5
IMPORTANT: It is also possible to connect more components than specified above,
if the sum of the »required power« of the »ACTIVE components« does not exceed 2500 mA.
e.g.: 20 stop points, of which 10 pcs. are »ACTIVE« 10 x 138 mA = 1380 mA
20 branches, electrical, of which 8 pcs. are »ACTIVE« 8 x 138 mA = 1104 mA
SUM = 2484 mA
20 2 LED bar spotlights 40 x 60 mA = 2400 mA
There is a remaining amount of 516 mA for components to be activated by »buttons«.
These are: 3 pcs. of stop points or
3 pcs. of branches or
2 pcs. - one stop point and one branch
Application: Manual control of the FALLER Car System
Functioning:
A Rectifier It transforms AC into DC.
The rectifier is connected to a transformer 12 -16 V AC,
e.g. FALLER transformer Art. No. 180641.
Switching of the individual components by:
Art. No.: 161675 Stop point Switch
Art. No.: 161677 Branch, electrical Button (without series resistor) or
Switch (with 47-Ohm series resistor)
Art. No.: 161676 Branch Button
Art. No.: 161674 Parking lot Button
Art. No.: 16168 .. Magnet enable coil Button
B Connection diagram Various examples for FALLER Car System components.
Button T ... Instantaneous switch Voltage only as long as button is operated.
Switch S ... Continuous - ON / OFF Voltage is permanently ON / OFF.
Technical data:
180633 rectifier Input voltage 12 - 16 V AC
Current input up to 3000 mA AC (5 - 10 minutes)
Output voltage at 12 VAC approx. 16.9 V DC
(unloaded) at 16 VAC approx. 22.6 V DC
Max. continuous current loading 2500 mA DC