INSTRUCTION MANUAL
SMOKE ALARM FS-588HLL
Read the instruction manual before use
FEATURES
Photoelectric smoke detection
Normal detection mode and low sensitivity detection mode (Hush)
Built-in 10-year sealed lithium battery
End of life warning
Low voltage warning
Low power consumption
SPECIFICATIONS
Technical Parameters:
Model Number: FS-588HLL
Detection Type: Photoelectric Sensor
Working Voltage: 3V DC (built-in)
Current: Quiescent Current: 2uA
Working Current: ≤ 120mA
Alarming Decibel: 85dB/3m
LED Indicator: LED (Red), LED (Green)
Working Temperature: -10˚C ~ +40˚C
Working Humidity: ≤ 95%RH (no condensation)
Status Display:
Standby Status
Red LED flashes every 344 seconds, no alarm sound
Smoke Detection or Test
Red LED flashes and continuous alarm is sounding
Low Sensitivity Detection
(Silent mode)
Red LED flashes every 10 seconds, no alarm sound.
Low sensitivity detection mode will cancel after 10
minutes.
Alarm Memory
Green LED flashes 3 times every 43 seconds, and
stops after 24 hours. The first time you press the
TEST/HUSH button after alarm is made, the detector
will hint by special alarm mode.
End of useful life
After 10 years of operation, alarm will sound 3 times
every 43 seconds
Low voltage status
Red LED flashes once and low battery beep every 43
seconds
SMOKE ALARM PLACEMENT
Minimum coverage is one unit for every floor, in every sleeping area, or in every
bedroom. For additional coverage, Family Shield recommends you install units in all
rooms, halls, and storage areas where temperatures normally remain between -10˚C
and 40˚C.
Do not mount the smoke alarm in:
a) A room in which the temperature can reach below -10˚C and above 40˚C
b) Damp spaces and areas with high humidity
c) Directly in front of doors or windows
d) Near a ventilator or radiator
e) Near appliances or areas where normal combustion regularly occurs
(kitchens, near furnaces, hot water heaters)
f) Extremely dusty, dirty, or insect-infested areas where loose particles
interfere with smoke alarm operation
g) Distances under 50 cm from fluorescent lights or low-energy bulbs
It is not recommended for this product to be installed in high humidity, dusty or high
temperature environments such as the kitchen or bathroom.
BATTERY PIN
(RED)
Question and Answer IconNeed help?

Do you have a question about the FAMILY SHIELD FS-588HLL and is the answer not in the manual?

Summary

Technical Parameters

Status Display

Details the indicators for standby, smoke detection, low sensitivity, alarm memory, end of life, and low voltage.

Smoke Alarm Placement

Prohibited Placement Locations

Lists specific locations where the smoke alarm should not be mounted due to environmental factors or proximity to heat sources.

Installation Guide

Battery Activation and Initial Test

Instructions for activating the battery pin and performing the initial test of the smoke alarm's functionality.

Mounting the Smoke Alarm

Steps for securely attaching the smoke alarm base plate to the ceiling and connecting the alarm unit.

Maintenance and Troubleshooting

Regular Maintenance

Guidance on cleaning the smoke alarm to ensure optimal performance and prevent dust accumulation.

Troubleshooting Common Failures

Identifies common issues like failure to sound or low battery beeps and provides solutions.

Important Warnings

Crucial safety advice regarding unwanted alarms and battery replacement.

Overview

The device described is a Family Shield FS-588HLL Smoke Alarm, a photoelectric smoke detector designed for household use.

Function Description

The primary function of the FS-588HLL is to detect smoke and alert occupants with a loud alarm. It utilizes photoelectric sensing technology, which is effective at detecting slow-burning fires. The device includes a "Hush" mode (low sensitivity detection) to temporarily silence nuisance alarms, and an alarm memory feature to indicate if an alarm has previously been triggered. It is powered by a built-in 10-year sealed lithium battery, eliminating the need for battery replacement throughout its operational life. The device also provides warnings for low battery and end-of-useful-life.

Important Technical Specifications

  • Model Number: FS-588HLL
  • Detection Type: Photoelectric Sensor
  • Working Voltage: 3V DC (built-in battery)
  • Quiescent Current: ≤ 2uA
  • Working Current: ≤ 120mA
  • Alarming Decibel: ≥85dB/3m (at 3 meters)
  • LED Indicators: Red (for alarm/status) and Green (for alarm memory)
  • Working Temperature: -10°C to +40°C
  • Working Humidity: ≤ 95%RH (non-condensing)
  • Battery: Built-in 10-year sealed lithium battery (not replaceable)
  • Certifications: CE15, EN14604: 2005 / AC: 2008, LPCB (1275a/01)

Usage Features

  • Standby Status: Red LED flashes every 344 seconds, with no alarm sound.
  • Smoke Detection/Test: Red LED flashes and a continuous alarm sounds.
  • Low Sensitivity Detection (Hush Mode): Activated by pressing the TEST/HUSH button during a nuisance alarm. Red LED flashes every 10 seconds, with no alarm sound. This mode automatically cancels after 10 minutes.
  • Alarm Memory: After an alarm, the green LED flashes 3 times every 43 seconds for up to 24 hours. Pressing the TEST/HUSH button after an alarm will cause the detector to hint by a special alarm mode. Releasing the button disables alarm memory.
  • End of Useful Life Warning: After 10 years of operation, the alarm will sound 3 times every 43 seconds.
  • Low Voltage Status: Red LED flashes once and a low battery beep sounds every 43 seconds.
  • Installation: The device is installed by rotating the base anticlockwise to remove it, switching the battery pin from OFF to ON, fixing the base plate to the ceiling with screws, and then fastening the smoke alarm to the base by turning it clockwise.
  • Testing: The smoke alarm can be tested by firmly pushing the TEST/HUSH button. A loud beep should sound, stopping when the button is released.
  • Placement Recommendations: Minimum coverage is one unit per floor, in every sleeping area, or every bedroom. For additional coverage, units should be installed in all rooms, halls, and storage areas where temperatures remain between -10°C and 40°C.
  • Avoid Placement In:
    • Rooms with temperatures outside -10°C to +40°C.
    • Damp spaces or areas with high humidity.
    • Directly in front of doors or windows.
    • Near ventilators or radiators.
    • Near appliances or areas with regular normal combustion (e.g., kitchens, furnaces, hot water heaters).
    • Extremely dusty, dirty, or insect-infested areas.
    • Within 50 cm of fluorescent lights or low-energy bulbs.
    • High humidity, dusty, or high-temperature environments like kitchens or bathrooms are not recommended.

Maintenance Features

  • Regular Testing: The smoke alarm should be tested regularly using the TEST/HUSH button.
  • Cleaning: The smoke alarm should be cleaned at least once a month to remove dust, dirt, or debris. This involves vacuuming all sides and the cover of the smoke alarm with a soft brush or wand attachment, ensuring all vents are free of debris. A damp cloth can be used to clean the cover if necessary.
  • Important Cleaning Note: The cover should NOT be removed to clean inside the smoke alarm, as this will void the warranty.
  • Battery: The built-in 10-year lithium battery is not replaceable.
  • Troubleshooting: A troubleshooting guide is provided for common issues such as the alarm not sounding when tested (check if battery pin is ON), circuit failure, or low battery (contact retailer).
  • Alarm Response: If the alarm sounds and it is not being tested, it indicates smoke detection, requiring immediate attention. Do not switch off the battery to quiet an unwanted alarm; instead, fan the air or open a window to remove smoke or dust.

FAMILY SHIELD FS-588HLL Specifications

General IconGeneral
BrandFAMILY SHIELD
ModelFS-588HLL
CategorySmoke Alarm
LanguageEnglish