INSTRUCTION MANUAL
SMOKE ALARM FS-588HLL
Read the instruction manual before use
FEATURES
Photoelectric smoke detection
Normal detection mode and low sensitivity detection mode (Hush)
Built-in 10-year sealed lithium battery
End of life warning
Low voltage warning
Low power consumption
SPECIFICATIONS
Technical Parameters:
Model Number: FS-588HLL
Detection Type: Photoelectric Sensor
Working Voltage: 3V DC (built-in)
Current: Quiescent Current: 2uA
Working Current: ≤ 120mA
Alarming Decibel: 85dB/3m
LED Indicator: LED (Red), LED (Green)
Working Temperature: -10˚C ~ +40˚C
Working Humidity: ≤ 95%RH (no condensation)
Status Display:
Standby Status
Red LED flashes every 344 seconds, no alarm sound
Smoke Detection or Test
Red LED flashes and continuous alarm is sounding
Low Sensitivity Detection
(Silent mode)
Red LED flashes every 10 seconds, no alarm sound.
Low sensitivity detection mode will cancel after 10
minutes.
Alarm Memory
Green LED flashes 3 times every 43 seconds, and
stops after 24 hours. The first time you press the
TEST/HUSH button after alarm is made, the detector
will hint by special alarm mode.
End of useful life
After 10 years of operation, alarm will sound 3 times
every 43 seconds
Low voltage status
Red LED flashes once and low battery beep every 43
seconds
SMOKE ALARM PLACEMENT
Minimum coverage is one unit for every floor, in every sleeping area, or in every
bedroom. For additional coverage, Family Shield recommends you install units in all
rooms, halls, and storage areas where temperatures normally remain between -10˚C
and 40˚C.
Do not mount the smoke alarm in:
a) A room in which the temperature can reach below -10˚C and above 40˚C
b) Damp spaces and areas with high humidity
c) Directly in front of doors or windows
d) Near a ventilator or radiator
e) Near appliances or areas where normal combustion regularly occurs
(kitchens, near furnaces, hot water heaters)
f) Extremely dusty, dirty, or insect-infested areas where loose particles
interfere with smoke alarm operation
g) Distances under 50 cm from fluorescent lights or low-energy bulbs
It is not recommended for this product to be installed in high humidity, dusty or high
temperature environments such as the kitchen or bathroom.
BATTERY PIN
(RED)
Question and Answer IconNeed help?

Do you have a question about the FAMILY SHIELD FS-588HLL and is the answer not in the manual?

FAMILY SHIELD FS-588HLL Specifications

General IconGeneral
BrandFAMILY SHIELD
ModelFS-588HLL
CategorySmoke Alarm
LanguageEnglish

Summary

Technical Parameters

Status Display

Details the indicators for standby, smoke detection, low sensitivity, alarm memory, end of life, and low voltage.

Smoke Alarm Placement

Prohibited Placement Locations

Lists specific locations where the smoke alarm should not be mounted due to environmental factors or proximity to heat sources.

Installation Guide

Battery Activation and Initial Test

Instructions for activating the battery pin and performing the initial test of the smoke alarm's functionality.

Mounting the Smoke Alarm

Steps for securely attaching the smoke alarm base plate to the ceiling and connecting the alarm unit.

Maintenance and Troubleshooting

Regular Maintenance

Guidance on cleaning the smoke alarm to ensure optimal performance and prevent dust accumulation.

Troubleshooting Common Failures

Identifies common issues like failure to sound or low battery beeps and provides solutions.

Important Warnings

Crucial safety advice regarding unwanted alarms and battery replacement.