Model FT-N010
Particulate Respirator N95
User Instructions
(Keep insert for reference)
Warning
This respirator helps protect against certain particles. Misuse may result in sickness or
death. For proper use, see supervisor, User Instructions, or call +86-512-65586028 / 65586038
Company Name: Suzhou Fangtian Industries Co., Ltd.
Address: Xiehe Building, No.158 Jinmen Road, Suzhou City, Jiangsu, P. R. China
Fax: +86-512-65586018
E-mail:
ftefire@pub.yc.jsinfo.net, ftefire@126.com
http://www.chinamasks.com/
Rev. A
6/1/2010
Question and Answer IconNeed help?

Do you have a question about the Fangtian Industries FT-N010 and is the answer not in the manual?

Summary

Respirator Safety and Usage

General Warning

Crucial safety alert regarding potential sickness or death from misuse.

Respirator Instructions and Limitations

Use Limitations

Specific conditions and environments where the respirator is unsuitable for use.

Fitting Instructions

Step-by-step guide for achieving a proper face seal with the respirator.

Use Instructions

Guidelines for correct application and duration of respirator use.

NIOSH Approval and Configuration

Protection Details

Information on the respirator's filter efficiency and protection level.

Cautions and Limitations

Regulatory cautions and usage limitations for approved respirator configurations.

Overview

The FT-N010 Particulate Respirator N95 is a personal protective device designed to help protect against certain airborne particles. Manufactured by Suzhou Fangtian Industries Co., Ltd., this respirator is approved by NIOSH under the TC-84A-SFIN010Ba configuration, indicating its compliance with N95 particulate filter standards. The N95 classification signifies that the respirator has a 95% filter efficiency level against particulate aerosols that are free of oil. It is important to note that time use restrictions may apply for this type of protection.

Function Description:

The primary function of the FT-N010 respirator is to filter out airborne particulate matter, thereby reducing the wearer's exposure to harmful particles. It is specifically designed for environments where particulate aerosols are present and do not contain oil. The respirator is a "Cup" style, meaning it has a pre-formed, rigid shape that helps maintain its structure and distance from the wearer's face. This model does not include an exhalation valve, which means all inhaled and exhaled air passes through the filter material.

Important Technical Specifications:

  • Model: FT-N010
  • Protection Level: N95
  • Filter Efficiency: 95% against particulate aerosols free of oil.
  • Style: Cup
  • Valve: None
  • NIOSH Approval: TC-84A-SFIN010Ba
  • Manufacturer: Suzhou Fangtian Industries Co., Ltd.
  • Contact Information:
    • Address: Xiehe Building, No.158 Jinmen Road, Suzhou City, Jiangsu, P. R. China
    • Fax: +86-512-65586018
    • E-mail: ftefire@pub.yc.jsinfo.net, ftefire@126.com
    • Website: http://www.chinamasks.com/

Usage Features:

The FT-N010 respirator is intended for use in non-oil environments where particulate protection is required. Proper fitting is crucial for its effectiveness. The fitting instructions are as follows:

  1. Hold the respirator in one hand with the nosepiece at the fingertips, allowing the headbands to hang below the hand.
  2. Press the respirator against the face with the nosepiece on the bridge of the nose.
  3. Place the top band high on the back of the head. Move the bottom band over the head and position it below the ears.
  4. Using both hands, mold the nosepiece to the shape of the nose.
  5. Perform a fit test by cupping both hands over the respirator and exhaling vigorously. If air flows around the nose, tighten the nosepiece. If air leaks around the edges, reposition the bands for better fit.
  6. For fit-check of the face-seal: Place both hands over the respirator without disturbing its position. Since this model does not have an exhalation valve, exhale sharply. If air leaks are detected, readjust the head straps and/or position. If a satisfactory fit cannot be achieved, the user should NOT enter the contaminated area.

Limitations on Use:

  • Oxygen Levels: Not for use in atmospheres containing less than 19.5% oxygen.
  • IDLH Environments: Not for use in atmospheres immediately dangerous to life or health.
  • Concentration Limits: Do not exceed maximum use concentrations established by regulatory standards (e.g., 10 times the Permissible Exposure Limit, whichever is lower).
  • Specific Hazards: Not for protection against gases or vapors, oil aerosols (if using N protection class), sandblasting, paint-spray operations, or asbestos.
  • Unknown Contaminants: Not for use when contaminants or their concentrations are unknown.
  • Facial Hair: Do NOT use with beards or other facial hair that interferes with a direct contact between the face and the edge of the respirator, or any other conditions that may prevent a good face-seal.
  • Modification: Do NOT modify or misuse the respirator.
  • Allergic Reactions: Materials that come into contact with the wearer's skin could cause allergic reactions in susceptible individuals.

Maintenance Features:

The FT-N010 is a disposable respirator and is not designed for cleaning or reuse. It should be discarded and replaced with a new one if:

  • Excessive clogging causes breathing difficulty.
  • The respirator becomes damaged.
  • The user experiences dizziness, irritation, or other distress while wearing it in a contaminated area, indicating a potential failure of the respirator or an unsuitable environment.

General Use Instructions and Warnings:

  • Failure to follow all instructions and limitations can seriously reduce performance and lead to illness, injury, or death.
  • Users must be trained by their employer in the correct use of the respirator in accordance with applicable safety and health standards (e.g., OSHA 29 CFR 1910.134(e)(5) and CSA Z94.4-93).
  • Fit-testing is required for wearers.
  • Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration specified by the manufacturer.
  • Refer to user instructions and/or maintenance manuals for information on use and maintenance.
  • NIOSH does not evaluate respirators for use as surgical masks.
  • This respirator helps protect against certain particles, but it may not eliminate the risk of contracting disease or infection. Misuse may result in sickness or death.

Fangtian Industries FT-N010 Specifications

General IconGeneral
BrandFangtian Industries
ModelFT-N010
CategoryRespiratory Product
LanguageEnglish