13
Setup Commands
Command Function
SZ# Image Size
(0=Cropped, 1=Normal)
S# Scan Rate (0-8)
0= Line Doubled
1= Frame Doubled*
2= 800x600
3= 720p
4= 1024x768
5= Line Quadrupled (960p)
6= 1280x1024
7= 1080p
8= 1080i
W# Screen Shape,
(0=Widescreen, 1=4x3)
Fn Input Video Standard
0=1=Auto,2=PALN 3=PALM
M# Output Mode (0-2)
(0=RGB, 1=YCrCb, 2=YPrPb)
CS# Comp Sync
(1=On, 0=Off)
G# Sync on Green
(1=On, 0=Off)
HS# HD Pass Scan Rate (0-7)
0= 800X600
1= 1024X768
2= 1280X1024
3= 1600X1200
4= Custom 1
5= Custom 2
6= HDTV (720p or 1080i)
7= WVHS
HF# HD Frame Rate (0-2)
0 = 60Hz
1 = 75Hz
3 = 85Hz
OSDON Turn OSD On
OSDOFF Turn OSD Off
OV# OSD Vertical Start
(0=top off screen)
E0/E1 ECHO OFF/ON
Operation Commands
ON/OFF Power ON/OFF
HELP Display Help Menu
ST Report Current Status*
V Video
Y Y/C
X YCrCb
VP 480P
HDR HDTV Passthrough RGB
HDY HDTV Passthrough YUV
HDP HDTV Passthrough YPrPb
B# Brightness (0-255)
C# Contrast (0-255)
K# Color (0-255)
T# Tint (0-255)
N# Noise Reduction (0-15)
D# Detail (0-15)
A# Input Aspect Ratio (0-2)
(0=4x3, 1=Letterbox, 2=Anamorphic)
L# Store User Preset (1-4)
P# Recall Preset (0-4)
(1-4=User, 0=Factory)
P5 in the ST means something changed
since the last preset was recalled.
Infrared Control Notice: All commands via
Infrared are direct access. The Power
On/Off control is a two command macro. The
second command must occur within .25
seconds of the first command.
On Power, Function Up
Off Power, Function
RS232 Instructions