Technical Note
Date:
Tuesday, 9 June 2020
Applicable Equipment:
Tintmaster Dispensers (TM280 / TM300)
Subject:
Start-up process following a prolonged idle period
This is a guide to help prepare the Tintmaster Dispensers (TM280 / TM300) to normal operation after a
prolonged period of non-use.
Before trying to dispense colorant, please follow the steps below:
Tools
Paper towel / cloth / wet wipes for cleaning and/or to remove dried colorants
10 mm socket (to remove the side panels)
Anti mould spray if appropriate
Gloves and/or any other personal protective equipment recommended by site, employer, etc.
Procedure
1. Press E-Stop button on the dispenser
2. Check if the brush is clean, and that there is correct amount of cleaning liquid (water / solvent) in the
brush container
3. Open the canister lid one by one and check the colorant condition. If colorant is hardened, thickened
or mould has grown, take appropriate actions. You may need to contact the colorant supplier / paint
supplier for further instructions
4. Take off the side covers of the machine, and
a. Visually check the valve wiper and nozzle one by one.
i. Check to ensure the valve is returning to cover the nozzle. If not, the valve spring
and/or wiper pad may be damaged. Replace them or you may need to consult with
your service supplier
ii. Check to ensure that the valve wipers are clean. Remove any dried colorants
b. Clean the nozzles manually if you suspect colorant may have dried. Take off the nozzle one
by one, wash with warm water, and place back onto the pump. IMPORTANT: Ensure to place
the o-ring back into the nozzle. If o-rings are broken or damaged, you need to replace with
new ones.
c. Visually check and ensure that each pump disk is in the correct height. You may find some
pump disks are raised up, if so, then push them down to the correct height.
d. NOTE: You may need to close the covers, switch on the machine, turn the turn table to the
different position to be able to access all pumps. For safety, close the side covers every time
before switching on the machine
e. Close the side covers before you proceed to the next step
5. If dispenser is not connected to the power, connect to the power supply
6. Release the E-Stop button on the dispenser
7. Start up the PC if not yet done

Questions and Answers

  • A
    Allison HansonAug 16, 2025
    What to do if new software is not working on Fast & Fluid Management Dispenser?
    • B
      Brandon HamiltonAug 16, 2025
      If your Fast & Fluid Management Dispenser's software isn't working, the program may not have booted correctly, so reboot your computer and the software. Alternatively, the software might be incorrectly installed, in which case you should reinstall it.
  • D
    Danny BarnesAug 19, 2025
    Why is there no power from the power unit of my Fast & Fluid Management TM280?
    • V
      Vickie WalkerSep 12, 2025
      If your Fast & Fluid Management Dispenser shows no power, first check the power cables to ensure they are connected to the power grid. If the cables are fine, the fuse may have blown. Remove the plug from the socket and replace the fuse.
  • J
    Jerome HamiltonAug 22, 2025
    Why are colors difficult to reproduce with my Fast & Fluid Management TM280?
    • Y
      ywheelerAug 22, 2025
      If the colours are difficult to reproduce with your Fast & Fluid Management Dispenser, the mechanisms might be dirty, so clean and oil them. It could also be due to quality fluctuations in the paste supplied, in which case you should contact your paste supplier. Thickened pastes can also cause this issue, so replace any thickened paste(s). Finally, the turntable might be in the wrong position; reset it by pressing and unlocking the emergency stop button. Leaks around the pistons can also cause this problem. In this case, the pistons should be replaced “Service”.
  • K
    Kevin BaileyAug 26, 2025
    What to do if the keyboard is not working on my Fast & Fluid Management TM280?
    • M
      Marcus SkinnerAug 26, 2025
      If your Fast & Fluid Management Dispenser's keyboard isn't working, start by checking the cables to ensure they are properly connected. The issue may also be related to an incorrect Windows Regional setting, in which case you should check the Windows software manual. Defective cables or keyboard may also be a reason. In this case, the cables or keyboard should be replaced “Service”.
  • T
    Thomas BowenAug 28, 2025
    Why is the monitor picture poor or not showing on my Fast & Fluid Management TM280 Dispenser?
    • M
      Melissa MasonAug 28, 2025
      If the monitor picture is poor or there's no picture on your Fast & Fluid Management Dispenser, first ensure the monitor is switched on. Next, check the cables to make sure they are not loose. If the picture is too dark, adjust the picture settings correctly. If none of these steps work, the monitor may be malfunctioning “Service”.
  • P
    Patricia SpencerAug 31, 2025
    What to do if the stirrer is not rotating on my Fast & Fluid Management TM280 Dispenser?
    • A
      Alan MorenoAug 31, 2025
      If the stirrer is not rotating on your Fast & Fluid Management Dispenser, the timer setting may be incorrect. Set the timer correctly using the software. Also, check the cable to ensure it is not loose. Defective cable or motor may also be a reason. In this case, the cable or motor should be replaced “Service”.
  • J
    Jackie HahnSep 3, 2025
    Why is the turntable not turning on my Fast & Fluid Management Dispenser?
    • D
      Danielle CookSep 3, 2025
      If the turntable is not turning on your Fast & Fluid Management Dispenser, the piston rod may be positioned too high. Set the piston in a lower position. Also, check the cables to make sure they are not loose. Defective cable or motor may also be a reason. In this case, the cable or motor should be replaced “Service”.
  • D
    Derek AndersonSep 6, 2025
    What to do if air is being fed together with the paste in Fast & Fluid Management TM280 Dispenser?
    • S
      Sheryl FrancoSep 6, 2025
      If air is being fed together with the paste in your Fast & Fluid Management Dispenser, there may be an air bubble in the pump. Prime the pump to resolve this. Another possible cause is an empty canister; refill it. If the problem persists, the piston may be defective, in which case you should replace the pump “Service”.
  • B
    brettwilkersonSep 9, 2025
    Why is the valve leaking through the outlet opening of my Fast & Fluid Management TM280 Dispenser?
    • J
      Joseph SmithSep 9, 2025
      If the valve leaks through the outlet opening on your Fast & Fluid Management Dispenser, it could be due to an air bubble in the pump; prime the pump. Alternatively, the valve may be defective, and you should replace the pump “Service”.
  • C
    coletaraSep 12, 2025
    What to do if canister connection leaks around the suction point on Fast & Fluid Management TM280?
    • M
      Michael PattersonSep 12, 2025
      If the canister connection leaks around the suction point on your Fast & Fluid Management Dispenser, the O-ring(s) may be worn. Replace the O-ring(s) “Service”.