Chapter One: Setting Up FSMS
72 FedEx Ship Manager
®
Server User Guide, Version 7.6
Transactional Meter Configuration
The FSMS 070 Meter Query Request transaction was enhanced in FSMS to allow configuration changes
to the FSMS Configuration Utility using a transaction. This feature reduces the need to access the FSMS
Configuration Utility directly and allows the ability to make changes remotely. The following business rules
apply:
• The new configuration transaction does not allow adding or deleting a meter.
• Each meter must send a separate 070 transaction for configuration. For example, if you have one
Parent/Master meter and three Child meters, then four separate 070 transactions must be entered to
make configuration changes for all meters.
• The following fields from the FSMS Configuration Utility can be configured using the 070 transaction:
• All fields on the Doc-Tab screen
• Express DG Printer ID
• Express DG Printer Form Type
• Ground Hazmat Printer ID
• Express/Ground Commercial Invoice
• Ground Hazardous Materials Certification
• Client Name
• Client Version
• Middleware Name
• Middleware Version
• Time Zone
• Late Drop-Off
• Sender E-mail ID
• Variable Handling Fields
For more information regarding Remote Configuration using the 070 transaction set, please see the
FSMS TCR Version 7.6.