1-800-888-2418 | www.feeneyinc.com 1
Installa on Instruc ons
Drivers are available in a variety of wa ages. In general a driver should not exceed more than 80% of its rated wa age.
(Example: 60W Driver = 60 x 0.8 = 48W Max).
Strip Lights require 1.44 wa s per foot. A er determining the necessary length of strip ligh ng, calculate the wa age and ensure the
driver being used has adequate capacity. (Example: 10’ = 10 x 1.44 = 14.4W)
The maximum length of strip ligh ng that can be connected in one run is 25 feet. If one sec on of ligh ng is longer than 25 feet, it
must be broken into mul ple smaller sec ons and run on separate circuits.
Building codes vary by loca on and jurisdic on. Consult all applicable codes before installing DesignRail® LED Ligh ng.DesignRail®
LED Ligh ng may not be suitable for every applica on and it is the sole responsibility of the installer to ensure that DesignRail® LED
Ligh ng is used for its intended purpose.
WARNING: ELECTRIC SHOCK IS ALWAYS POSSIBLE WHEN WORKING WITH ELECTRICITY. THIS CAN CAUSE SERIOUS PERSONAL
INJURIES OR DEATH. ELECTRICAL SHORTS CAN ALSO CAUSE FIRES AND PROPERTY DAMAGE. ALWAYS MAKE SURE THE
ELECTRICAL OUTLET YOU ARE PLUGGING INTO IS GROUNDED.
for DesignRail
®
24VDC LED Ligh ng