fencee power DUO RF PDX10
1,4 J 1 J 9000 V 5000 V
fencee power DUO RF PDX20
3 J 2 J 12 000 V 6000 V
fencee power DUO RF PDX30
4,5 J 3 J 11 200 V 6400 V
fencee power DUO RF PDX40
5,7 J 4 J 10 000 V 5500 V
fencee power DUO RF PDX50
7,5 J 5 J 11 000 V 6600 V
fencee power DUO RF PDX70
10 J 7 J 10 500 V 7500 V
35 km 8 km 2 km 1,5 km
60 km 15 km 3 km 1,5 km
100 km 23 km 5 km 2 km
120 km 30 km 8 km 3 km
140 km 40 km 10 km 4 km
180 km 70 km 17 km 8 km
CEE
TEOR. MAX
fencee p owe r DUO RF P DX10
fencee po w e r DUO RF P DX20
fencee po w e r DUO RF P DX30
fencee po w e r DUO RF P DX40
fencee po w e r DUO RF P DX50
fencee po w e r DUO RF P DX70
230V ~ / 12 V
Safe Animal Management
|
Power supply - 230 V~ / 12 V
Electric fencing
+420 730 893 828
www.fencee.eu
EN
INSRUCTION FOR USE
Smart Farm fencee
Cloud System is
protected in the EU
utility model.

Questions and Answers

  • A
    austingardnerAug 16, 2025
    How to troubleshoot Fencee Fencing & Gates energizer not working?
    • C
      curtissparksAug 16, 2025
      To address a Fencee Fencing & Gates energizer that isn't working, first, disconnect it from the fence system and switch it on again. If the blue or violet LED is lit and the yellow or green LED is flashing on the bargraph indicator, the device is functioning correctly. If not, the device may be damaged, and you should contact your dealer. For battery and accumulator devices, ensure the correct wiring of the poles.
  • J
    Jason CarterAug 19, 2025
    Why is the red LED light blinking on my Fencee Fencing & Gates?
    • S
      Sandra OneillAug 19, 2025
      If the red LED light on your Fencee Fencing & Gates system is blinking, it means the battery voltage has dropped below 12 V. Replace the battery with a sufficiently charged one or connect an adapter.
  • M
    Michael DavisAug 22, 2025
    What to do if no LED signal is burning on Fencee Fencing & Gates?
    • C
      carolshepherdAug 22, 2025
      If no LED signal is lit on your Fencee Fencing & Gates energizer, it may be switched off manually, or the battery voltage may have dropped below 11.4 V, causing it to switch off automatically. Replace the battery with a sufficiently charged one or connect an adapter. The red LED will remain lit until the battery voltage reaches at least 12 V.
  • E
    erobertsAug 26, 2025
    Why is red LED blinking and siren beeping on Fencee power DUO RF PDX10?
    • A
      Andrea EdwardsAug 26, 2025
      If the red LED light is blinking and a warning siren is sounding (beeping) on your Fencee Fencing & Gates, it indicates that the battery voltage has dropped below 11.6 V. Replace the battery with a sufficiently charged one or connect an adapter.
  • A
    Alyssa ScottAug 28, 2025
    How to fix Fencee power DUO RF PDX10 Fencing & Gates conductor with adverse properties?
    • E
      Erin ThompsonAug 28, 2025
      If your Fencee Fencing & Gates conductor has adverse properties such as a thin diameter or high resistance, use a high-quality conductor with low resistance and a larger diameter. Also, ensure a high-quality and correct connection of conductors.
  • C
    Courtney WillisAug 31, 2025
    How to improve low-quality earthing for Fencee power DUO RF PDX10?
    • J
      Jamie HarveyAug 31, 2025
      If you have low-quality earthing, a too-short earth rod, corrosion, or dry soil affecting your Fencee Fencing & Gates system, add another rod and moisten the soil.
  • J
    jenniferloveSep 3, 2025
    How to stop lead-in via growth near Fencee Fencing & Gates?
    • M
      Matthew WhiteSep 3, 2025
      To resolve lead-in issues due to growth near your Fencee Fencing & Gates system, remove the growth by mowing it.
  • M
    Monica BeckerSep 6, 2025
    What to do if Fencee power DUO RF PDX10 Fencing & Gates conductor is on the ground?
    • B
      Brent BrownSep 7, 2025
      If the conductor is on the ground due to a break or insufficient mechanical tension in your Fencee Fencing & Gates system, repair the fencing, use special connectors, and stretch the conductor.
  • M
    Matthew FloresSep 9, 2025
    How to fix conductor connected via knot in Fencee power DUO RF PDX10?
    • V
      Veronica Harris MDSep 9, 2025
      If a conductor is connected via a knot, resulting in an insufficient connection in your Fencee Fencing & Gates system, use relevant special connectors for the conductor.
  • R
    Rebecca ValentineSep 12, 2025
    What to do if Fencee power DUO RF PDX10 remote controller doesn't work?
    • S
      Suzanne NealSep 12, 2025
      If your Fencee Fencing & Gates remote controller isn't working, replace the battery with a new one, ensuring correct polarity.