F-35-60H
February 2024
1
FEATURES
• Safe start with DETECT-A-FLAME
®
flame sensing
technology
• Custom pre-purge and inter-purge timings*
• Single or three trials for ignition
• System diagnostic LED
• Flame current test points
• Local or remote flame sensing
• Automatic reset**
• True Alarm output or NC (Normally Closed Contact)
• Meets 60730-2-5 Harmonized Standard
APPLICATIONS
• Commercial cooking
• Gas furnaces
• Boilers
• Water heaters
• Other gas-fired appliances
DESCRIPTION
The 35-60 is a 24 VAC direct spark ignition (DSI) control
designed for use in all types of gas-fired appliances. The control
uses a microprocessor circuit to provide precise, repeatable
timing and operating sequences. A diagnostic LED and optional
UART communications make troubleshooting easy and ensures
safe and efficient operation.
The optional UART communications offers advanced diagnostic
data and connectivity with the Fenwal ConnectedControl series
05-50 Wi-Fi device.
Export Information (USA)
Jurisdiction: EAR
ECCN: EAR99
Agency Certifications
SPECIFICATIONS
C22.2 No.0:20
ANSI Z21.20-2014
CAN/CSA C22.2 No. 60730-1:13
RoHS Compliant
Input Power Control: 18-30 VAC 50/60Hz
(Class 2 transformer)
Input Current 300 mA @24 VAC with gas valve
relay energized (control only)
Gas Valve 2.0A max @ 24 VAC
Operating Temperature -40°F to +176°F
(-40°C to +80°C)
Storage Temperature -40°F to +185°F
(-40°C to +85°C)
Flame Sensitivity
0.7
µA minimum
Flame Failure Response 0.8 seconds maximum
Gas Types Natural, LP, or manufactured
Spark Rate: 50/60 sparks/sec
Size (LxWxH)
with enclosure
5.69 x 3.94 x 1.87 inches
(14.45 x 10.01 x 4.75 cm)
Moisture Resistance Conformal coated to operate non-
condensing to 95% R.H. Module
should not be exposed to water
Ingress Protection Not rated, protection provided by
appliance in which it is installed
Tries for Ignition One or three try versions available
Trial for Ignition Periods 4, 7, 10, 15 seconds available
Pre-purge and
Inter-purge Timings
0, 15 or 30 seconds available
Ignition Method Sparking pulses 600 mS On,
400 mS Off
Communications Optional UART communication
SERIES 35-60 - 60730-2-5 Compliant
24 VAC Microprocessor-Based Direct Spark Ignition Control