MDS
MDS
Page 22
* Residential Complex
WXYZ
TUVPQR
GHI MNO
DEF
ABC
JK L
3
4
21
7
8
65
9
0
A
BC
*
#
123
456
789
A0B
LCD DIGITAL SYSTEM
123
456
789
A0B
LCD DIGITAL SYSTEM
123
456
789
A0B
LCD DIGITAL SYSTEM
123
456
789
A0B
LCD DIGITAL SYSTEM
123
456
789
A0B
LCD DIGITAL SYSTEM
TELEFONOS
D2
BUS
+
D1
-
62
PGM
12
1
1643
2
423
3
D1
BUS
26
D2
3
5
-
-+
V
646
6
21
7
342
13261
4
64 423 6
6 3
8
614213421
REF. 2425
TELEFONOS
D2
BUS
+
D1
-
62
PGM
12
1
1643
2
423
3
D1
BUS
26
D2
3
5
-
-+
V
646
6
21
7
342
13261
4
64 423 6
6 3
8
614213421
REF. 2425
123
456
789
A0B
LCD DIGITAL SYSTEM
Example of a call from system. MDS Digital - MDS City
WXYZ
TUVPQR
GHI MNO
DEF
ABC
JK L
3
4
21
7
8
65
9
0
A
BC
*
#
B
26
FXLPANEL 0
2
+-
SBSA CT6 VM AB GA
12Vdc
REF. 2405
UNIDAD CENTRAL MDS
MDS CENTRAL UNIT
DECODERS
D2 D1
+-
M V
-
+
G
CN1
CN2
CN8
CN7
SA
SB
CT
M
V
6
2
-
+
CN3
SA
M
CT
V
SB
6
2
-
+
CN4
CN5
CN6
OUT
IN
+- + -
SW1
SW2
ON ON
CN1
CN2
CN8
CN7
SA
SB
CT
M
V
6
2
-
+
CN3
SA
M
CT
V
SB
6
2
-
+
CN4
CN5
CN6
OUT
IN
+- + -
SW1
SW2
ON ON
123
456
789
A0 B
LCD DIGITAL SYSTEM
123
456
789
A0 B
LCD DIGITAL SYSTEM
123
456
789
A0 B
LCD DIGITAL SYSTEM
12 Vdc
TELEFONOS
D2
BUS
+
D1
-
62
PGM
12
1
1643
2
423
3
D1
BUS
26
D2
3
5
-
-+
V
646
6
21
7
342
13261
4
64 423 6
6 3
8
614213421
REF. 2425
TELEFONOS
D2
BUS
+
D1
-
62
PGM
12
1
1643
2
423
3
D1
BUS
26
D2
3
5
-
-+
V
646
6
21
7
342
13261
4
64 423 6
6 3
8
614213421
REF. 2425
12 Vdc
TELEFONOS
D2
BUS
+
D1
-
62
PGM
12
1
1643
2
423
3
D1
BUS
26
D2
3
5
-
-+
V
646
6
21
7
342
13261
4
64 423 6
6 3
8
614213421
REF. 2425
TELEFONOS
D2
BUS
+
D1
-
62
PGM
12
1
1643
2
423
3
D1
BUS
26
D2
3
5
-
-+
V
646
6
21
7
342
13261
4
64 423 6
6 3
8
614213421
REF. 2425
12 Vdc
HIGH PERFORMANCE
MULTIPLEXED DIGITAL SYSTEM
STOP
HIGH PERFORMANCE
MULTIPLEXED DIGITAL SYSTEM
STOP
HIGH PERFORMANCE
MULTIPLEXED DIGITAL SYSTEM
STOP
Decoder Programming:
From: 101 to 140.
Decoder Programming:
From: 1201 to 1280.
Note:
In Interior Blocks remember that when programming
decoders, the first two digits of the number assigned to
the decoders (residence number) should match the inte-
rior block number.
For example forBBVV, it will be BB: Block (the initial 0 is
not included) - VV: Residence
* Block 1: From 101 to 140
* Block 12: From 1201 to 1280
The Block Number must always be programmed on the
corresponding Internal Block Panel. In MDS City Panels
(Digitiser) programming is carried out from the MDS Digital
Panel in the General Entrance.
Access 1
BLOCK 1
Access 1
BLOCK 2
Access 2
- Call residence 0058 in Block 12
Press: 1 2 5 8
Calls from the GENERAL ENTRANCE
in this case,
the first two
digits match
the block
number (12)
in this case, the first
two digits match the
block number (01)
- Call residence 0027 in Block 1
Press: 1 2 7
(the initial 0s are not included)
residence
number
(2 digits)
block
number
(2 digits)
residence
number
(2 digits)
block
number
(2 digits)
in this type of call, the
panel’s digitiser adds
the block number called
as a prefix, in this case
block number: 1
- Call residence 0027 in Block 1
Press: 2 7
(button)
Calls from the INTERIOR BLOCK
- Call residence 0058 in Block 12
Press: 5 8
(button)
in this type of call,
the panel’s
digitiser adds the
block number
called as a prefix,
in this case block
number: 12
residence
number
(2 digits).
The button
determines the
last 2 digits in
the call address
block
number
(2 digits)
block
number
(2 digits)
residence
number
(2 digits).
The button
determines the
last 2 digits in
the call address
Panel installed in:
General Entrance
Interior Blocks
System Chosen:
MDS Digital
MDS Direct
Residences per Block
B1 B12
3 General Entrances
General Entrance
Guard Unit
Residence 58
MDS Address 1258
Residence
27
MDS Address 0127
Residential
Floors
40 80