What to do if the supply voltage is under 180V for my ferolli BlueHelix ALPHA C Boiler?
- JJustin GreenSep 18, 2025
If the supply voltage is under 180V for your Ferolli Boiler, check the electrical system.
What to do if the supply voltage is under 180V for my ferolli BlueHelix ALPHA C Boiler?
If the supply voltage is under 180V for your Ferolli Boiler, check the electrical system.
What to do if there is no flame after the ignition phase in my ferolli BlueHelix ALPHA C?
If your Ferolli Boiler fails to maintain a flame after ignition, start by inspecting the ionization electrode for proper positioning and any deposits; perform a complete manual calibration, replacing the electrode if necessary. Also, check the burner itself, make sure that air/fume ducts are clear of obstructions, and inspect the trap for any blockages. Finally, ensure that the calibration is correct by performing a complete manual calibration.
How to fix incorrect system water pressure in my ferolli BlueHelix ALPHA C Boiler?
If your Ferolli Boiler displays incorrect system water pressure, fill the system if the pressure is too low. If that doesn't resolve the issue, check the water pressure switch.
Why is the overtemperature protection intervention occurring in my ferolli BlueHelix ALPHA C?
If your Ferolli Boiler is experiencing overtemperature protection intervention, first check the heating sensor's position and operation, replacing it if necessary. Next, verify that there's proper water circulation in the system by checking the circulating pump. Finally, vent the system to eliminate any air that may be trapped.
What to do if my ferolli BlueHelix ALPHA C Boiler shows the wrong supply frequency?
If your Ferolli Boiler is showing the wrong supply frequency, check the electrical system.
What causes a parasite flame signal after valve closing in my ferolli BlueHelix ALPHA C Boiler?
Check the correct position and condition of the electrode. Check the PCB. Check the gas valve and replace it if necessary.
What causes a specific flame combustion error in a Ferolli Boiler?
If your Ferolli Boiler shows a specific flame combustion error, check the gas supply, fume ducts, and condensate drain. Verify the correct position and state of the electrode. The error should reset after about 3 minutes.
How do I fix a card parameter fault on my Ferolli Boiler?
If your Ferolli Boiler is showing a card parameter fault, check and if necessary modify parameter b15 to 3.
What causes a DHW sensor fault in a ferolli BlueHelix ALPHA C?
If your Ferolli Boiler is showing a DHW sensor fault, check the wiring or replace the sensor.
What causes a flow sensor fault in a ferolli BlueHelix ALPHA C?
If your Ferolli Boiler is displaying a flow sensor fault, check the wiring or replace the sensor.
Defines the warranty's scope and duration for product conformity.
Outlines the procedure for claiming warranty services and authorized support.
Lists conditions and damages that are not covered by the warranty.
Specifies cases where the conventional warranty becomes invalid.
Clarifies the responsibilities of the installer and the manufacturer regarding installation.
Explains consumer rights under EU directives and national law.
Provides an overview of the boiler and its key features.
Details the functions and symbols of the boiler's control panel.
Covers connecting power, turning the unit on/off, and initial states.
Guides on setting heating/DHW temps, modes, and advanced adjustments.
General guidelines and safety requirements for boiler installation.
Specifies suitable locations and ventilation requirements for installation.
Instructions for making water and heating circuit connections.
Details on connecting the gas supply safely and correctly.
Guidelines for electrical wiring, grounding, and safety precautions.
Information on installing and connecting fume exhaust ducts and ventilation.
Instructions for connecting the condensate drain line and its safety aspects.
Covers gas conversion, combustion checks, calibration, testing, and heat capacity adjustments.
Steps to follow for the initial startup and testing of the boiler.
Guidelines for periodic maintenance and safely opening the boiler casing.
Diagnostic procedures for identifying and resolving boiler faults and errors.
Physical dimensions and connection ports for the boiler models.
Diagrams showing major internal components and their labels.
Schematic representation of the boiler's internal hydraulic system.
Comprehensive tables of technical specifications and ErP data.
Graphical representations of boiler performance characteristics.
Electrical schematic showing component connections and wiring.