[1-10]
Suction power adjuster
[1-11]
Switch
[1-12]
Locking clip
[1-13]
Dust container
[1-15]
Brake
The specified illustrations appear at the begin
ning of the Operating Instructions.
4 Technical data
Mobile dust extractors
Power consumption 350 ‑ 1200 W
Maximum appliance socket connected load EU
CH, DK
GB 240 V/ 110 V
2400 W
1100 W
1800 W/ 500 W
Max. suction capacity (air), turbine 234 m³/h (3900 l/min)
Max. vacuum, turbine 24000 Pa
Filter surface area 6318 cm²
Suction hose D 27 mm x 3,5 m‑AS
Length of the net cable 7.5 m
Sound pressure level as per EN 60704-2-1 / Uncertainty K 71 dB(A) / 3 dB
Protection category IP X4
Container capacity CTM 26 E, CTM 26 E AC 26 l
CTM 36 E, CTM 36 E LE, CTM 36 E AC, CTM 36 E LE AC, CTM 36 E AC-LHS 36 l
CTM 48 E, CTM 48 E LE, CTM 48 E AC, CTM 48 E LE AC 48 l
Dimensions L x W x H CTM 26 E, CTM 26 E AC 630 x 365 x 540 mm
CTM 36 E, CTM 36 E LE, CTM 36 E AC, CTM 36 E LE AC, CTM 36 E AC-LHS 630 x 365 x 596 mm
CTM 48 E, CTM 48 E LE, CTM 48 E AC, CTM 48 E LE AC 740 x 406 x 1005 mm
Weight CTM 26 E 13.9 kg
CTM 26 E AC 14.7 kg
CTM 36 E, CTM 36 E LE 14.4 kg
CTM 36 E AC, CTM 36 E LE AC, CTM 36 E AC-LHS 15.2 kg
CTM 48 E, CTM 48 E LE 18.8 kg
CTM 48 E AC, CTM 48 E LE AC 19.6 kg
5 Intended use
Mobile dust extractor suitable for
– Extracting dust up to 0,1 mg/m³ according
to dust class 'M', including wood and paint
dust,
– Extracting water,
– Increased loads during commercial use,
according to IEC/EN 60335-2-69.
The user is liable for improper or non-in
tended use.
6 Operation
WARNING
Unauthorised voltage or frequency!
Risk of accidents
► Observe the specifications on the ma
chine’s name plate.
► Observe country-specific regulations.
6.1 Initial operation
English
15