ADVANCED PARAMETERS
23. Key Pressed 2 times – value of SWITCH ON command sent to
3rd association group
This parameter denes value of SWITCH ON command sent to devices
in 3rd association group after a double click.
Available settings: 1-255 - sent value
Default setting: 99 Parameter size: 2 [bytes]
24. Key Pressed 3 times – command sent to 3rd association group
This parameter denes commands sent to devices associated in 3rd
association group after a triple click.
Available settings: 0 - no action
1 - SWITCH ON
2 - SWITCH OFF
3 - SWITCH ON/OFF – alternately
Default setting: 0 Parameter size: 1 [byte]
25. Key Pressed 3 times – value of SWITCH ON command sent to
3rd association group
This parameter denes value of SWITCH ON command sent to devices
in 3rd association group after a triple click.
Available settings: 1-255 - sent value
Default setting: 255 Parameter size: 2 [bytes]
29. Key Held Down – command sent to 3rd association group
This parameter denes commands sent to devices associated in 3rd
association group after holding the button down.
Available settings: 0 - no action
1 - START LEVEL CHANGE UP (brightening)
2 - START LEVEL CHANGE DOWN (dimming)
3 - START LEVEL CHANGE UP/DOWN (brighten-
ing/dimming) – alternately
Default setting: 3 Parameter size: 1 [byte]
30. Alarm frame triggers
Parameter determines which actions result in sending alarm frames
to 4th association group.
Available settings: 1 - Key Pressed 1 time
2 - Key Pressed 2 times
4 - Key Pressed 3 times
8 - Key Pressed 4 times
16 - Key Pressed 5 times
32 - Key Held Down
64 - Key Released
Default setting: 127 (all) Parameter size: 1 [byte]