11
ADVANCED PARAMETERS
14. Key Pressed 3 times – command sent to 2nd association group
This parameter denes commands sent to devices associated in 2nd
association group after a triple click.
Available settings: 0 - no action
1 - SWITCH ON
2 - SWITCH OFF
3 - SWITCH ON/OFF – alternately
Default setting: 0 Parameter size: 1 [byte]
15. Key Pressed 3 times – value of SWITCH ON command sent to
2nd association group
This parameter denes value of SWITCH ON command sent to devices
in 2nd association group after a triple click.
Available settings: 1-255 - sent value
Default setting: 255 Parameter size: 2 [bytes]
20. Key Pressed 1 time – command sent to 3rd association group
This parameter denes commands sent to devices associated in 3rd
association group after a single click.
Available settings: 0 - no action
1 - SWITCH ON
2 - SWITCH OFF
3 - SWITCH ON/OFF – alternately
Default setting: 3 Parameter size: 1 [byte]
21. Key Pressed 1 time – value of SWITCH ON command sent to
3rd association group
This parameter denes value of SWITCH ON command sent to devices
in 3rd association group after a single click.
Available settings: 1-255 - sent value
Default setting: 255 Parameter size: 2 [bytes]
22. Key Pressed 2 times – command sent to 3rd association group
This parameter denes commands sent to devices associated in 3rd
association group after a double click.
Available settings: 0 - no action
1 - SWITCH ON
2 - SWITCH OFF
3 - SWITCH ON/OFF – alternately
Default setting: 1 Parameter size: 1 [byte]