Care and maintenance
After each use:
- Make sure that the Jet motor is turned off, wait for impeller to come to a complete
stop
- Remove Impeller housing from magnetic motor and disassemble
- Sanitize Impeller assembly(Jet Cover, Impeller, and Motor base/shaft) & basin
bowl with Anti-Bacterial Solution(DO NOT USE ACETONE)
- Rinse Impeller assembly and basin bowl with cool water
- Massage Chair upholstery can be cleaned with a clean damp cloth, clean off any
residue left from pedicure after each use to prevent stains.
End of the day:
- Check all air, water, and electrical connections for cracks, leaks, or damage
- Wipe down chair/basin with damp cloth to prevent stains
- Dust/clean control box with dry cloth or duster to prevent overheating
Periodic Maintenance
- Inspection/lubrication of massage roller and track is required every 6 months to
ensure proper function and long service life.
- Prior to inspection please ensure that the unit is off and unplugged.
- To get to massage rollers, begin by removing the covers on the front of the chair,
and removing the black friction cloth by unzipping on all sides.
- Inspect motor track(white delrin tracks on the left and the right) for damage or
foreign objects, as well as proper lubrication(light film of grease on the track)
- If the track seems dry or under lubricated, lubricate using white lithium grease that
can be purchased from local auto parts store.