Diesel Generator
D0128008
D0128008
Question and Answer IconNeed help?

Do you have a question about the Firman SDG2500CL and is the answer not in the manual?

Summary

Safety Precautions

Exhaust Fumes Precautions

Safety measures for handling exhaust gases, including carbon monoxide risks and ventilation.

Refueling Safety Guidelines

Safe practices for refueling, such as stopping the engine and managing fuel spills.

Battery Charging Safety

Precautions for handling battery electrolyte and ensuring proper charging environment.

General Safety Tips

Warnings about hot parts and proper generator placement.

Generator Usage Precautions

Guidelines for safe operation, including avoiding tipping, covering, and electrical hazards.

Name of Parts

Generator Components

Identification of key external parts of the diesel generator set.

Engine and Chassis Parts

Identification of engine-related components and chassis features.

Specifications

Main Technical Specifications

Detailed technical data for various generator models.

Basic Operating Parameters

Conditions for optimal performance and reliable operation of the generator set.

Before Starting

Engine Oil Handling

Guidance on checking, selecting, and using engine oil for proper lubrication.

Fuel Oil Selection

Recommendations for using appropriate diesel fuel oil and handling it safely.

Starting Procedures

Recoil Starting

Step-by-step instructions for starting the generator using the recoil starter.

Electric Starting

Instructions for starting the generator using the electric starter key.

Battery Maintenance

Guidance on checking and maintaining the battery fluid level for reliable starting.

Operating Your Generator Set

Generator Warm-up

Procedure for warming up the generator engine before applying load.

Operation Checks

Regular checks to monitor the generator's performance during operation.

Applying Load

Instructions for connecting appliances and applying electrical load to the generator.

Stopping Your Generator Set

Shutdown Procedure

Step-by-step guide to safely stop the generator engine.

Emergency Stop

Methods for stopping the engine if it does not respond to normal controls.

Periodic Checks and Maintenance

Maintenance Schedule Overview

Table detailing maintenance tasks based on operation hours and time intervals.

Engine Oil Maintenance

Procedure for changing engine oil.

Oil Filter Maintenance

Instructions for cleaning or replacing the oil filter.

Air Cleaner Element Maintenance

Guidance on changing the air cleaner element.

Fuel Filter Maintenance

Instructions for cleaning or replacing the fuel filter.

Specialized Maintenance

Tasks requiring special tools or dealer assistance, like nozzle and piston ring checks.

Long Term Storage

Storage Preparation

Steps for preparing the generator for extended storage.

Storage Procedure

Actions to take for engine and parts protection during storage.

Overview

This document is an owner's manual for a Firman Diesel Generator, identified by part number D0128008. The manual outlines the safe and proper operation, as well as essential maintenance procedures, for the generator set.

Function Description:

The Firman Diesel Generator is designed to produce electric power using a diesel engine. It serves as a portable power source for various electric appliances. The generator features both AC and DC output capabilities, with specific voltage and amperage ratings for each. It is equipped with an engine speed lever to control operation and a fuel tank for diesel light oil. The generator also includes safety features such as an AC breaker and a DC breaker to protect against overcurrent. Starting the generator can be done via two methods: recoil starting or electric starting, providing flexibility depending on user preference or conditions. The engine is an air-cooled, 4-cycle diesel engine, designed for reliable performance.

Usage Features:

Before operation, users are instructed to place the generator on a flat, horizontal surface. The manual emphasizes the importance of checking the engine oil level and ensuring it is within the recommended range, as insufficient or excessive oil can damage the engine. Proper fuel selection is critical, with a strict recommendation to use only diesel light oil with a cetane value of more than 45 to prevent starting difficulties, misfiring, and white exhaust smoke. Refueling must be done in a well-ventilated area with the engine stopped, and users are warned against overfilling the tank.

For recoil starting, the fuel cock must be in the "Open" position, and the engine speed lever set to "RUN." The recoil starting handle is pulled with a specific technique, including pushing down the decompression lever. In cold weather, adding a small amount of engine lube oil to the cylinder head bonnet is suggested for easier starting. For electric starting, the fuel cock is opened, the engine speed lever is set to "RUN," and the starting key is turned clockwise to "START." Users are advised to release the key as soon as the engine starts and to wait briefly between starting attempts to avoid draining the battery.

During operation, the generator should be warmed up without load for approximately 3 minutes. The manual highlights that CX series generators are equipped with a low oil warning system, which will automatically stop the engine if oil pressure is low or lubrication oil is scarce. Users are cautioned against loosening or readjusting the engine speed limiting bolt or fuel injection limiting bolt, as these are factory-adjusted settings that affect performance. When connecting appliances, the AC breaker should be set to "ON," and the generator must reach its rated speed. For DC applications, correct polarity must be observed. The manual also advises against connecting instruments that require excessive starting current or exceed the rated current of the socket to prevent damage to the machine.

Stopping the generator involves several steps: setting the AC breaker to "OFF," unplugging appliances, moving the engine speed lever to low speed for 3 minutes without load, then to "STOP." For electric-start models, the starter key is returned to "OFF," and the fuel chock lever is set to "S" (closed). Finally, the recoil handle is slowly pulled to the point of compression to prevent rust formation. Users are warned against stopping the engine suddenly or using the decompression lever for stopping, as this can lead to abnormal temperature rises.

Maintenance Features:

The manual provides a detailed maintenance schedule, categorizing checks and maintenance tasks by daily, first month (or 20 hours), every 3 months (or 100 hours), every 6 months (or 300 hours), and every year (or 1000 hours). Key maintenance tasks include checking and tightening bolts and nuts, checking and resupplying engine oil, and replacing engine oil. The oil filter needs to be cleaned every 3 months or 100 hours. The air cleaner element, which is a wet type, should be changed every 6 months or 300 hours (or earlier if dirty), and users are warned not to wash it with detergent or run the engine without it.

The fuel filter requires cleaning every 3 months or 100 hours and replacement every 6 months or 300 hours to ensure maximum engine output. Tasks such as checking the fuel injection nozzle, fuel injection pump, and fuel piping, as well as adjusting intake/exhaust valves head clearance and checking/lapping intake/exhaust valve seats, are marked as requiring special tools and skills, indicating that a dealer should be contacted for these services. Replacing piston rings also falls under this category. Battery liquid levels should be checked monthly, and distilled water added if the level drops below the lower mark.

For long-term storage, specific preparations are outlined to prevent damage and rust. This includes operating the engine for 3 minutes before stopping, draining the used engine oil while warm, and refilling with new oil. A small amount of engine lube oil should be added to the cylinder head bonnet for 2500 and 4000 series models. The engine should then be turned over a few times without starting, either by pulling the recoil starter with the decompression lever down or by turning the starter key for electric-start models. Finally, the decompression lever is pulled up, and the recoil starter is slowly pulled until resistance is felt, closing the intake and exhaust valves to prevent rust. The generator should then be cleaned and stored in a dry place.