8. STORAGE
DRAIN
SCREW
The following procedures should be followed prior to storage of your generator for
periods of 3 months or longer.
Drain fuel from fuel tank carefully. Gasoline left in the fuel tank will eventually
deteriorate making engine-starting difficult.
Loosen the drain screw on the bottom of the carburetor float chamber, and drain the
fuel completely.
Change engine oil.
Check for loose bolts and screws, tighten them if necessary.
Clean generator thoroughly with oiled cloth. Spray with preservative if available.
NEVER USE WATER TO CLEAN GENERATOR.
Pull starter handle until resistance is felt, leaving handle in that position.
Store generator in a well ventilated, low humidity area.