English Customer Service: 1-844-FIRMAN1
09
Control Panel
NOTICETotal power drawn from all receptacles must not exceed the data decal rating.
1. Engine Start Switch To start engine, press and hold the switch in the START (ll) position, the
engine will crank and attempt to start. When the engine starts, release the switch to the RUN (l) position.
2. Economy Control Switch - The Economy Control switch can be activated in order to minimize
fuel consumption and noise while operating the unit during times of reduced electrical output,
allowing the engine speed to idle during periods of non-use. The engine speed returns to normal
when an electrical load is connected. When the economy switch is off, the engine runs at normal
speed continuously.
6
7
9. 120V, 30A RV – NEMA TT-30R
A maximum of 22.9 Amps current may be drawn from this receptacle.
1
3
2
5
4
8
9
10
11
12
13
14
15
16
17
18
3. CO Alert™ Carbon Monoxide (CO) Shutdown Indicator LightIndicates the engine shutdown due
to carbon monoxide accumulation around the generator or a CO Alert system fault occurred.
4. Intelligauge with LED ScreenThe screen can show the Voltage, Hertz, Power , running hours, Fault
alarm, regular maintenance, low oil alarm and remaining running time .
5. Battery Power Restore Switch
6. USB-C Output/Input Port
Devices that charge through a USB-C port, such as a MacBook Pro, Android phone, or other devices
can be charged by the USB-C port(5V, 9V, 12V, 15V & 20V output 60W maximum.).
The battery can be charged through USB-C port. USB-C charging input supports 5V/3A input 15W
maximum.
7. DC 12V Output - 8.3 Amps of DC current may be drawn from this receptacle. Use this outlet to charge
12V automotive type batteries ONLY. See 12V DC outlet (Battery Charger) section.
8. 20A Circuit Breaker – The receptacles are protected by AC circuit protectors.
11. Ground Terminal – Consult an electrician or authority having jurisdiction for local grounding
requirements.
10. 120V, 20A Duplex GFCI (Ground Fault Circuit Interrupter)- NEMA 5-20R
A maximum of 20 Amps current may be drawn from this duplex receptacle.