EasyManua.ls Logo

Firman WH03242 - Page 32

Firman WH03242
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English Customer Service: 1-844-FIRMAN1
Maintenance Valve Clearance
Intake: ( )
Exhaust: 0.004 – 0.006 in. (0.10 – 0.15 mm)
0.004 – 0.006 in. 0.10 – 0.15 mm
Muffler and Spark Arrester
WARNING! Contact with muffler area could cause burns resulting in serious injury.
Do not touch hot parts.
It is a violation of California Public Resource Code, Section 4442, to use or operate the engine
on any forest-covered, brush-covered, or grass-covered land unless the exhaust system is
equipped with a spark arrester, as defined in Section 4442, maintained in effective working
order. Other states or federal jurisdictions may have similar laws, reference Federal
Regulation 36 CFR Part 261.52.
30
Maintenance - Storage
(d) Inspect spark plug for damage and clean with a wire brush before reinstalling. Replace if
damaged.
SPARK PLUG: FIRMAN P/N 330723001
(e) For spark plug FIRMAN P/N 330723001 - Adjust the electrode gap to 0.020 - 0.024 in. ( 0.5 - 0.6 mm).
(f) Seat spark plug in position and thread by hand to prevent cross threading.
(g) Tighten plug with provided wrench and put the spark plug boot back on spark plug.
0.020-0.024 in.
(0.5-0.6mm)
SPARK PLUG: FIRMAN P/N 330723001