EasyManuals Logo

First Alert 7010B User Manual

First Alert 7010B
7 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
REGULAR MAINTENANCE
Use only the replacement batteries listed below. The unit may not
operate pr
operly with other batteries. Never use rechargeable batteries
since they may not provide a constant charge.
This unit has been designed to be as maintenance-fr
ee as possible, but ther
e
are a few simple things you must do to keep it working properly:
T
est it at least once a week.
Clean the Smoke Alarm at least once a month; gently vacuum the
outside of the Smoke Alarm using your household vacuum’
s soft brush
attachment. Test the Smoke Alarm. Never use water, cleaners or solvents
since they may damage the unit.
If the Smoke Alarm becomes contaminated by excessive dirt, dust and/or
grime, and cannot be cleaned to avoid unwanted alarms, replace the
unit immediately
.
Relocate the unit if it sounds frequent unwanted alarms. See “Locations
To Avoid For Smoke Alarms” for details.
Model 7010B Only: When the battery back-up becomes weak, the
Smoke Alarm will “chirp” about once a minute (the low battery warning).
This warning should last 7 days, but you should replace the battery
immediately to continue your pr
otection.
Model 7010B Only
Choosing a replacement battery:
Y
our Smoke Alarm requires one standard 9V battery. The following batteries
a
re acceptable as replacements: Duracell #MN1604, (Ultra) #MX1604;
Eveready (Energizer) #522. You may also use a Lithium battery like the Ultralife
U
9VL-J for longer service life between battery changes.
T
hese batteries are
a
vailable at many local retail stores.
A
ctual battery service life depends on the smoke alarm and the environment
in which it is installed. All the batteries specified above are acceptable
r
eplacement batteries for this unit. Regardless of the manufacturer’s suggested
b
attery life,
y
ou MUST replace the battery immediately once the unit
starts “chirping” (the “low battery warning”).
WEEKLY TESTING
NEVER use an open flame of any kind to test this unit. You might
accidentally damage or set fire to the unit or to your home. The built-
in test switch accurately tests the unit’s operation as required by
Underwriters Laboratories, Inc. (UL).
If the Alarm ever fails to test properly, replace it immediately.
Products under warranty may be returned to the manufacturer
for
replacement. See “Limited Warranty” at the end of this manual.
DO NOT stand close to the Alarm when the horn is sounding. Exposure
at close range may be harmful to your hearing. When testing, step away
when horn starts sounding.
It is important to test this unit every week to make sure it is working
properly. Using the test button is the recommended way to test this
Smoke Alarm.
Press and hold the test button on the cover of the unit until
the alarm sounds (the unit may continue to alarm for a few seconds after you
release the button). If it does not alarm, make sure the unit is receiving power
and test it again. If it still does not alarm, replace it immediately.
During testing,
you will hear a loud, repeating horn pattern: 3 beeps, pause, 3 beeps,
pause.
When testing a series of inter
connected units you must test each unit individ
-
ually. Make sure all units alarm when each one is tested.
U
NDERSTANDING THE INDICATOR LIGHTS
AND ALARM HORN PATTERNS
N
OTE: When power is applied, unit(s) may alarm momentarily.
*
When any Smoke Alarm in an interconnected series triggers an alarm, its
red LED will flash rapidly. The red LEDs will remain OFF on any remaining
a
larms in the series. This feature helps responders identify which unit(s)
triggered the alarm.
A
C Power
A
ll Models
D
C Power
M
odel 7010B
Normal Operation Constant Green LED
Flashing Red LED
a
pprox. once/minute
N
o Audible Alarm
Green LED Off
F
lashing Red LED
approx. once/minute
No Audible Alarm
Test Condition Constant Green LED
R
apidly Flashing
R
ed LED
A
udible Alarm
Green LED Off
R
apidly Flashing
R
ed LED
A
udible Alarm
Silence Mode Red LED flashes once
e
very 10 seconds
Red LED flashes once
e
very 10 seconds
A
larm Condition*
(Initiating Unit)
C
onstant Green LED
R
apidly Flashing
R
ed LED
Audible Alarm
G
reen LED Off
R
apidly Flashing
Red LED
Audible Alarm
L
ow Battery
N
ot Applicable Alarm “chirp’’ approx.
o
nce/minute
5
IF THIS SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
D
uring an alarm, you will hear a loud, repeating horn pattern:
3 beeps, pause, 3 beeps, pause.
I
f the unit alarms and you are not testing the unit, it is warning you of a
potentially dangerous situation that requires your immediate attention.
NEVER ignore any alarm. Ignoring the alarm may result in injury or
d
eath.
Never disconnect the AC power to quiet an unwanted alarm.
Disconnecting the power disables the Alarm so it cannot sense
smoke. This will remove your protection. Instead, open a window or
f
an the smoke away from the unit. The Alarm will reset automatically.
If the unit alarms get everyone out of the house immediately.
ELECTRICAL SHOCK HAZARD: Attempting to disconnect the power
connector from the unit when the power is on may result in electrical
s
hock, serious injury or death.
When an interc
onnected system of AC powered units is in alarm, the alarm
i
ndicator light on the unit(s) that initiated the alarm will blink rapidly. It will
remain OFF on any remaining units.
I
f the unit alarms, get everyone out of the dwelling immediately.
If the unit alarms and you are certain that the source of smoke is not a fire—
cooking smoke or an extremely dusty furnace, for example—open a nearby
window or
door and fan the smoke away from the unit (Use the Silence Feature
to silence the Alarm). This will silence the alarm, and once the smoke clears the
unit will reset itself automatically.
WHAT TO DO IN CASE OF FIRE
Don’t panic; stay calm. Follow your family escape plan.
Get out of the house as quickly as possible. Don’t stop to
get dressed or collect anything.
Feel doors with the back of your hand before opening them.
If a door is cool, open it slowly. Don’t open a hot door. Keep doors
and windows closed, unless you must escape through them.
Cover your nose and mouth with a cloth (preferably damp).
Take short, shallow breaths.
Meet at your planned meeting place outside your home,
and do a head count to make sure everybody got out safely.
Call the Fire Department as soon as possible from outside.
Give your addr
ess, then your name.
Never go back inside a burning building for any reason.
Contact your Fire Department for ideas on making your home safer.
Alarms have various limitations. See "Limitations of Smoke Alarms" for
details.
USING THE SILENCE FEA
TURE
The Silence Featur
e can temporarily quiet an unwanted alarm for up to 15
minutes.
The Silence Feature does not disable the unit—it makes it temporarily
less sensitive to smoke. For your safety, if smoke around the unit is dense
enough to suggest a potentially dangerous situation, the unit will stay in
alarm or may re-alarm quickly. If you do not know the source of the
smoke, do not assume it is an unwanted alarm. Not responding to an
alarm can result in property loss, injury, or death.
T
o silence Smoke Alar
ms in an inter
connected series:
1. To silence multiple alarms in an interconnected series, you must press the
T
est/Silence button on the unit(s) that trigger
ed the alarm.
2. Once you activate the Silence feature, the Red LED will flash approximately
once every 10 seconds.
3. Pressing the Test/Silence button when in silence will restart the silence
timer
.
The Silence Feature on these units can temporarily quiet an unwanted alarm for
up to 15 minutes. T
o use this featur
e, press the Test/Silence button on the cover.
If the unit will not silence and no heavy smoke is present, or if it stays in
silence mode continuously, it should be replaced immediately.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the First Alert 7010B and is the answer not in the manual?

First Alert 7010B Specifications

General IconGeneral
Model7010B
TypeSmoke Alarm
Power Source120V AC
SensorPhotoelectric
Silence FeatureYes
Test ButtonYes
StandardsUL 217
Alarm Sound Level85 dB at 10 feet
Battery Backup9V
LED IndicatorYes
InterconnectivityYes