When used with the FA148CP/FA168CPS control
panels, address 16 must be assigned to the first
keypad. Additional keypads must be assigned to
address 17–23. Continue with the following.
SETTING THE KEYPAD OPTIONS
The procedures that follow are used to set the keypad address,
voice chime mode, and additional voice keypad mode.
Setting The Keypad Address
The keypad can either be set for an address of 00-30 or for non-
addressable mode (31). The default keypad address is 31. For
valid address settings for your keypad, refer to the control
panel's Installation & Setup Guide.
Note:
•
If unable to enter the address mode, power down, power
up, and try again.
•
If 10 seconds pass with no key entry, the keypad
automatically exits the address mode. You must power
down, power up, and start the address mode again.
•
The keypad will not enter the address mode if the
control panel is in programming mode.
1.
Apply power to the keypad.
2.
Within 60 seconds of applying power to the keypad, press
and hold down the [1] key and [3] key at the same time for 3
seconds. The current keypad address will be displayed.
3.
Press "00".
The current address is cleared.
4.
Enter desired keypad address.
5.
Press [
✱
] to save the displayed address and advance to the
Voice Chime prompt. "VOICE CHIME" (alpha keypad) or
"C" (fixed keypad) is displayed along with the selected mode
"1" or "0".
Setting The Voice Chime Mode
1.
Press the [1] key to set the Voice Chime mode on or press the
[0] key to set the Voice Chime mode off.
2.
Press [
✱
] key to save and advance to the Additional Keypad
voice keypad mode.
"ADDITIONAL CON" (alpha keypad) or "A" (fixed keypad)
is displayed along with the selected mode "1" or "0".
Note:
Setting Voice Chime mode off does not effect the voice
status or alarm annunciation.
Setting The Additional Keypad Mode
The Additional Keypad mode must be set for all voice keypads
being used.
1.
Set the voice keypad Additional Keypad mode as follows:
a.
On the Primary voice keypad, press [0] to set the
Additional Keypad mode to NO.
b.
On any secondary voice keypads, press [1] to set
Additional Keypad mode to YES.
2.
Press
[
✱
]
to save the mode.
VIEWING THE KEYPAD ADDRESS
Press and hold down the [1] key and [3] key at the same time
for about 3 seconds. The current address is displayed. No key
entry is allowed. Press any key to exit or wait 10 seconds to
exit the viewing mode.
SPECIFICATIONS
Physical:
7-5/16"H x 5-3/8"W x 1-3/8"D
Display:
2 x 16 Alpha-Numeric Super twist LCD (backlit)
Sounder:
Speaker
Electrical:
Voltage:
+12VDC
Current:
190mA (ARMED LED lit, LCD backlight and
sounder on) reduces to 60mA when panel is
operating in standby mode (backlight off).
TABLE 1. ZONE DESCRIPTORS AND INDEX ENTRIES
ALARM
002
DOOR
057
KITCHEN
105
PATIO
146
UPSTAIRS
207
ATTIC
009
EMERGENCY
067
LAUNDRY
106
POLICE
151
UTILITY
208
BABY
012
EXIT
071
LIBRARY
109
POOL
152
WINDOW
217
BACK
013
FIRE
079
LIVING
113
ROOM
162
YARD
223
BASEMENT
016
FLOOR
080
MAIN
122
SHED
168
ZONE
225
BATHROOM
017
FRONT
085
MASTER
123
SHOP
170
1ST
228
BEDROOM
019
GARAGE
089
MEDICAL
125
SIDE
173
2ND
230
CLOSED
040
GUN
094
MOTION
131
SLIDING
175
3RD
232
DEN
050
HALL
095
OFFICE
136
SMOKE
176
DETECTOR
052
HOUSE
099
OPEN
138
STORAGE
185
DINING
053
INSIDE
101
PANIC
144
SUPERVISED
190
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR