Step 6 - Re-assemble and install
6.1 - Mount channel assembly to door with channel
underneath new hinge stile bracket. Attach device to
lock stile and tighten screws, then tighten hinge stile
bracket mounting screws.
6.2 - Make wiring power connections and test for
proper Motor operation. Power Supply MUST be class
II rated in order to meet UL listing requirements.
6.3 - Re-assemble pushbar onto channel and
activating assemblies by sliding onto pins of
activating brackets pins will only fit in lower
pushbar slots.
6.4 - Make sure the pushbar bracket stop tabs are
installed with tabs turned up, away from the channel.
6.5 - Reinstall end caps.
Step 6.2 Plug polarity
Step 6.3 Slide pushbar
Onto hinge stile activating
assembly with pins in
lower slots
Step 6.4 Position
pushbar bracket on
lock stile activating
assembly with
tabs pointing up