Indoor air flow (Hi/Lo) m3/h 1050/900 1600/1420 1750/1500
Indoor noise level (Hi/Lo) dB(A) 43/40 47/44 47/44
Dimension(W*D*H) Body mm 840X240X840 840X310X840 840X310X840
Dimension(W*D*H) Panel mm 950X40X950 950X40X950 950X40X950
Packing (W*D*H) Body mm 1020X330X930 1020X400X930 1020X400X930
Packing (W*D*H) Panel mm 1030X145X1030 1030X145X1030 1030X145X1030
et/Gross weight Body Kg 36/46 40/50 40/50
Indoor unit
Net/Grossweight Panel Kg 6/11 6/11 6/11
Model YDK53-6H
YDK250-6D-WL YDK65-6WL;
YDK65-6FC
Brand WELLING WEILING WEILING
Input W 140
307
138+156
Capacitor uF 3
10μ
3.5x2
Outdoor fa
motor
Speed r/min 800
740
800
umber of rows 2 2 2
Tube pitch(a)x row pitch(b) mm 25.4x22 25.4x22 25.4X22
Fin spacing mm 1.5 1.7 1.8
Fin type (code)
Hydrophilic aluminium Unhydrophilic aluminium Unhydrophilic aluminium
Tube outside dia.and type mm
Ф9.53,
innergroove tube
Ф9.53,
innergroove tube
Ф9.53,
bare tube
Coil length x height x width mm 850X810X44 955*915*44 715X1220X44
Outdoor coil
umber of circuits 2 8 4
Outdoor air flow m3/h 3000 5000 6000
Outdoor noise level dB(A)
52
57
57
Dimension(W*H*D) mm 895X860X330
990x960x360
940X1245X360
Packing (W*H*D) mm 972X9875X406
1120x1090x435
1018X1377X434
Outdoor
unit
et/Gross weight Kg 79/90
101/106
110/125
Refrigerant type g R407C/2500
R407C/2700
R407C/4050
Design pressure MPa 1.2/2.8
1.2/3.5
1.2/3.5
Liquid side/ Gas side mm
Ф9.53/Ф16 Ф12.7/Ф19.0 Ф12.7/Ф19
Max. refrigerant pipe length m 15 15 15
Refrigerant
piping
Max. difference in level m 5 5 5
Connection wiring mm2 No NO No
Plug type No NO No
Controller Remote Remote Remote
Operation temp
℃
17-30
17-30
17-30
Ambient temp
℃
—7-45 -7 ~ 45 —7~ 45
Notes: 1. Nominal cooling capacities are based on the following conditions:
Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB; Equivalent ref. Piping: 8m(horizontal)
2. Nominal heating capacities are based on the following conditions:
Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB; Equivalent ref. Piping: 8m(horizontal)
3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an
anechoic room.