Fisher MC-715 - TAPE DECK ELECTRICAL ADJUSTMENTS; HEAD AZIMUTH ADJUSTMENT

Fisher MC-715
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TAPE
DECK
ELECTRICAL
ADJUSTMENTS
EQUIPMENT
REQUIRED
VTVM
(2
sets)
Frequency
Counter
Dummy
Load
(320)
Dualtrace
Oscilloscope
Test
Tapes
+
3kHz
Test
Tape
(Example:
TEAC
MTT-111)
Speed
Adjustment
#
10OkHz
Test
Tape
(Example:
TEAC
MTT-114)
for
Head
Azimuth
Adjustment
Alignment
Tool
for
Tape
HEAD
AZIMUTH
ADJUSTMENT
Connect
a
dualtrace
oscilloscope
and
a
VTVM
to
both
channel
outputs
of
the
headphone
jack
as
illustrated.
Oscilloscope
Then,
set
the
dualtrace
oscilloscope
as
follows:
$
MODE
...........ccececeeeecieeees
savediensee
‘CHOP
(chopped)
#
SOURCE
...........cceebeeeeee
..
INT
(internal),
CH1
or
CH2
+
SWEEP
MODE...........
dieu
eiestuch
ea
AUTO
(automatic)
NOTE:
De
Adjust
the
field
on
the
oscilloscope
with
the
VOLT.
ADJ.
and
TIME
ADJ.
—~20-
1.
3.
Insert
a
10kHz
test
tape
(Example:
TEAC
MTT-1
14)
into
the
cassette
compartment.
.
While
playing
back
the
test
tape,
turn
the
azimuth
adjusting
screw
until
the
wave
forms
of
the
right
and
left
channels
are
superimposed
and
set
to
optimum
at
maximum
reading
on
the
VTVM.
Adjustment
Sie
Record/Playback
Head
Azimuth
Adjustment
Screw
After
the
adjustment,
secure
the
adjusting
screw
with
paint
or
glue.