- 3 -
This heater is designed and approved for use as a
construction heater under Standard ANSI Z83.7/
CGA 2.14. 2011.
We cannot anticipate every use which may be made
of our heaters. CHECK WITH YOU LOCAL FIRE
SAFETY AUTHORITY IF YOU HAVE QUESTIONS
ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat
producing products in specific applications. Your local
authority can advise you about these.
SPECIFICATIONS
Model …………………………………………………….…. FVP-750 Propane
FVN-750 Natural Gas
Input …………………………………………………….…... 750,000 btuh
Fuel …………………………………………………………. FVP-750 Propane
FVN-750 Natural Gas
Manifold Pressure …………………………………………. 1.50” W.C. Propane
2.20” W.C. NG
Maximum Inlet Pressure ………………………………… 14.0” W.C. Propane
14.0” W.C. NG
Ignition ……………………………………………………… Direct Spark Ignition
…….……………………………………………...… Thermostat Control
Air Circulation ………………………………………………. 7000 cfm
Fuel Consumption ………………………………………..... 37 lbs/hr Propane
806 cfh NG
Approved …………………………………………………..... cETLus listed