INSTALLATION GUIDE
HOW TO POSITION AND PROGRAM THE FLASH PROGRAMMER 2S
PRODUCT FUNCTIONS
Centralised programming for two heating zones
using two temperature modes:
- Comfort temperature
- Reduced temperature
Manual override function in comfort and reduced mode for each room.
PRINCIPLE OF OPERATION
Convectors equipped with a suitable electromechanical thermostat:
Reduced temperature obtained by supplying a resistance, which overrides the sensing element of the
thermostat.
Convectors equipped with a suitable electronic thermostat:
Reduced temperature achieved by delivering an alternating signal (coding adopted by all designers since
January 1994)
TECHNICAL CHARACTERISTICS
Time switch: Electronic clock with day and week programs.
Power backup: By lithium battery, backup guarantee for a total of 3 years minimum against mains failure
(battery life: 10 years)
Program increments: 1 minute
Number of zones: 2
Total maximum current rating: 0.5A
Dimensions: 167mm x 84mm x 44mm
INSTALLATION
1
Unscrew the time switch fixing
screw
2
Separate the base plate from
the casing using a screwdriver
3
Surface-Mounted base with 2off
screw fixings Ø3mm maximum
4
Electrical connections (see page 2)
IMPORTANT
Insert the flying
lead from the display panel into the
socket on the circuit board as shown
5
Put outer casing back on
6
Put back in and tighten the
time switch fixing screw
1
http://waterheatertimer.org/Intermatic-timers-and-manuals.html#thermostat
Question and Answer IconNeed help?

Do you have a question about the Flash Programmer 2 S and is the answer not in the manual?

Flash Programmer 2 S Specifications

General IconGeneral
BrandFlash
ModelProgrammer 2 S
CategoryThermostat
LanguageEnglish

Summary

Installation Guide

Connecting the Pilot Wire

Programming Operations

Programming Zone 1

Guide for setting first and second switching times for Zone 1 (Comfort/Reduced).

Operating Modes

Auto Mode

Explanation of Auto mode: programmed positions, no amendments, keys disabled except RESET.

Modifying or Cancelling Times

Modifying Switching Times

Steps to modify existing switching times, including day selection and time adjustment.

Deleting Effect on Days

Procedure to delete the effect of a switching time on specific days.

Adding Days to Switching Time

Instructions for adding days to an existing switching time.

Overriding Timer Mode

Permanent Override

How to permanently override the timer mode for both zones to Comfort or Reduced.

Temporary Override (Holidays)

How to temporarily override for a set period (hours or days) for holidays.