Table of Contents

Questions and Answers

  • M
    Michael PalmerAug 17, 2025
    What to do if Flexball WR CONTROLS 3500 Control Systems command station or actuators have no power?
    • B
      Brenda HuntAug 18, 2025
      If your Flexball Control Systems command station or actuators lack power, the issue might stem from a missing power supply. Start by inspecting and, if necessary, replacing the circuit breaker. Also, examine and repair any damaged supply cables. Ensure that the power supply connector of the actuator is wired with the correct polarity.
  • S
    Samuel EllisAug 20, 2025
    Why does my Flexball WR CONTROLS 3500 Control Systems actuator display show an error alarm?
    • T
      Tyler CohenAug 20, 2025
      If the actuator display of your Flexball Control Systems shows an error alarm due to overload or incorrect cable positioning, it may be caused by a push-pull cable that has become too hard or a cable stroke that is not set correctly or push-pull cables not functioning correctly. First, turn off the system and identify the causes that might have triggered the alarm. Replace any push-pull cables that are not functioning correctly. Only restart the electronic control system after addressing the issues.
  • N
    Nancy StevensAug 22, 2025
    How to fix extra load on Flexball WR CONTROLS 3500 Control Systems push-pull cables?
    • N
      Nicole DavisAug 22, 2025
      If you notice an extra load on the push-pull cables or suspect an incorrect setting of the push-pull cable strokes in your Flexball Control Systems, you should replace the defective push-pull cable and re-program the strokes of the push-pull cables.
  • T
    Tanya CarrollAug 25, 2025
    What to do if Flexball Control Systems engine switches off during navigation?
    • J
      Jose PattersonAug 26, 2025
      If the engine switches off during navigation with your Flexball Control Systems, try turning the ignition key off and then on again. Alternatively, move the lever to neutral or press 'Command' and then 'Warm-up'.
  • N
    Nathaniel GeorgeAug 27, 2025
    What if Flexball WR CONTROLS 3500 Control Systems actuators have the same CANBus address?
    • R
      Ricky MurrayAug 27, 2025
      If two actuators in your Flexball Control Systems have the same CANBus address and are receiving commands from the same lever, program dip-switch JP14 according to the following: JP14 = OFF for the left actuator; JP14 = ON for the right actuator. Verify also that JP19 is programmed according to the installation scheme that you have chosen.
  • B
    Brittany TurnerAug 30, 2025
    Why Flexball Control Systems push-pull cable doesn’t reach neutral position?
    • W
      williamsrobertAug 30, 2025
      If the push-pull cable of the gearbox hasn’t come to the assigned neutral position in your Flexball Control Systems, check and remove any obstacle which doesn’t permit the actuator to go to neutral position.
  • J
    James WilliamsSep 1, 2025
    How to resolve Flexball WR CONTROLS 3500 Control Systems command stations with same CANBus address?
    • J
      Jessica BlankenshipSep 1, 2025
      If two command stations in your Flexball Control Systems have the same CANBus address, you must re-assign the CANbus addresses on the command station, set correctly the dip-switches positioned below the command station.
  • J
    Jennifer GarciaSep 4, 2025
    What to do if Flexball WR CONTROLS 3500 LEDs blink but command station doesn’t work?
    • C
      Chris CervantesSep 4, 2025
      If the 4 LEDS blink twice at power on but then the green LEDS are off and the command station doesn’t take the command for your Flexball Control Systems, program dip-switches according to your installation scheme.
  • N
    Nicholas NunezSep 6, 2025
    How to disable Synchro mode on Flexball WR CONTROLS 3500 Control Systems command station?
    • D
      Danielle HarrisSep 6, 2025
      If your Flexball Control Systems command station is in Synchro mode, de-activate the Synchro mode with the push-buttons on the command station.
  • T
    Terri VillaSep 9, 2025
    Why Flexball Control Systems engine doesn’t accelerate but gear engages?
    • M
      Mark KelleySep 9, 2025
      If the engine doesn’t accelerate but it is possible to engage the gear with your Flexball Control Systems, check the stroke of the gearbox and reprogram the gearbox stroke.