11
Cause Fault Remedy
Chainsaw does not operate No current supply Check current supply.
Defective outlet Try a different source of current,
change as necessary.
Extension cable damaged Check cable, replace if necessary.
Defective fuse Replace fuse
Chainsaw operates irregularly Mains cable damaged Take saw to a specialty workshop
External loose connection Take saw to a specialty workshop
Internal loose connection Take saw to a specialty workshop
Defective on/off switch Take saw to a specialty workshop
Saw chain dry No oil in the tank Re-ll oil
Ventilation in the oil tank cap clogged Clean oil tank cap
Oil tank ow channel clogged Unclog oil ow channel
Chain/guide rail hot No oil in the tank Re-ll oil
Ventilation in the oil tank cap clogged Clean oil tank cap
Oil tank ow channel clogged Unclog oil ow channel
Dull chain Re-sharpen or replace chain
Chainsaw jumps up, vibrates or
does not saw properly
Chain tension too loose Adjust chain tension
Dull chain Re-sharpen or replace chain
Chain worn out Replace chain
Saw teeth pulling in the wrong
direction
Re-mount saw chain with
teeth in the correct direction
15. EC Declaration of Conformity
We, ikra GmbH, Schlesierstraße 36, 64839 Münster GERMANY, declare under our sole responsibility that the
product Electric branch saw EAS 750F, to which this declaration relates correspond to the relevant basic safety
and health requirements of Directives 2006/42/EC (Machinery Directive), 2014/30/EU (EMC-Guideline), 2011/65/
EU (RoHS-Guideline) and 2000/14/EC (noise directive) incl. modications. For the relevant implementation of the
safety and health requirements mentioned in the Directives, the following standards and/or technical specication(s)
have been respected:
EN 60745-1:2009/A11:2010, EN ISO 11680-1:2011, AfPS GS 2014:01 PAK
EN 55014-1/A2:2011; EN 55014-2/A2:2008; EN 61000-3-2:2014; EN 61000-3-3:2013
Type examination certicate No. M6A 16 05 32082 134; TÜV SÜD Product GmbH, Identity no. 0123
measured acoustic capacity level 105,1 dB (A)
guaranteed acoustic capacity level 108,0 dB (A)
Conformity assessment method to annexe V / Directive 2000/14/EC
The year of manufacture is printed on the nameplate and can be additionally retrieved via the consecutive serial number.
Münster, 27.09.2016
Gerhard Knorr, Technical Management Ikra GmbH
Maintenance of technical documentation: Gerhard Knorr, Kärcherstraße 57, DE-64839 Münster