EasyManua.ls Logo

FLIGHT DESIGN CT - Section 12-10 - Replenishing; 12-10.1 General; 12-10.2 Replenishing Practices; 12-10.2.1 Refueling and Defueling

FLIGHT DESIGN CT
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document Title Document No. Revision
Date Section
Supplement S3 to the AMM CTLS-LSA –
CTLS-LSA with ROTAX 912iS
AF 0480 0011 00 05-Aug-12 12-10-1
Approval Ref.: Approved on the Basis of Manufacturer Self Declaration
SECTION 12-10 – REPLENISHING
12-10.1 General
This section provides instructions concerning replenishing procedures.
12-10.2 Replenishing Practices
12-10.2.1 Refueling and Defueling
Fuel content: 136 l (36) total, distributed to:
- 2 wing tanks each with 65 l (17.2 US.gal)
- one header tank with 6 l (1.6 US.gal).
Maximum Usable fuel: 130 l (34.3) total, provided by:
- 2 wing tanks each with 63 l (16.7 US.gal)
- one header tank with 4 l (1.1 US.gal).
Fuel specification: MOGAS EN228 Super;
MOGAS EN228 Super Plus;
AVGAS 100 LL (ASTM D910).
Note: The header tank has no separate filler opening. The header tank
automatically fills when the selected wing tank contains fuel.
12-10.2.1.1 Type of Maintenance
Line
12-10.2.1.2 Minimum Level of Certification
Pilot/Owner
12-10.2.1.3 Procedure
A. Recommended Special Tools and Parts
Item Quantity Unit
None
B. Refueling
Step Action Reference
1 Turn the engine off.
2 Set parking brake
3 Remove the filler cap situated on the upper surface of wing skin.
4 Fill the fuel tank with fuel
5 Install the fuel filler cap
6 Do steps 3-5 for the other wing