EN
Kits – FS34H90 & FS34H
Leak Detection & Automatic Water Shut-o System
Installation and Operating Manual
Congratulations on your purchase of a Floodstop electronic water leak detection and automatic water shut-o kit
for washing machines. This product has been designed to give you years of reliable service and minimize home
water damage by detecting water leaks and automatically shutting o the water supply.
To ensure proper installation and to maximize the performance of your Floodstop water leak detection system,
please read this manual thoroughly.
PLEASE READ CAREFULLY BEFORE PROCEEDING: If a leak is detected, the Floodstop Valves will shut o the water
going to the washing machine. This will stop the continuous ow of water from the water supply valve to the
washing machine. However, all or some of the water that is already in the washing machine and hoses may still
leak out onto the oor.
NOTE: This unit was shipped with an installation and operating manual that contains important information about
its operation. If you are installing this unit for use by others, we recommend you leave this manual – or a copy of
it – with the user.
Washing Machine Kit
FEATURES:
Control Panel has easy to read, lighted function buttons
AC Power with battery backup – For continued operation in the event of power outages
Solid brass, full port motorized ball valves for dependable, long lasting performance
Valves automatically shut-o the water supply when a leak is detected
Automatic monthly maintenance cycling of the valves to ensure reliable operation
Valves can be opened and closed with the touch of a button
Activates an audible alarm when a leak is detected
Mute button to silence the audible alarm
Can be reset and reused continuously with the touch of a button
Can be tested at any time with the touch of a button
Can accommodate additional water leak sensors
1 Year Limited Warranty
This Package Contains:
A (2) Floodstop Motorized Brass
Valves (3/4” FHT x 3/4” MHT)
B (1) Control Panel
C (1) Leak Sensor with Paper Sleeve
D (1) AC Adaptor
E (1) Wire Harness
F (1) Hook & Loop Mounting Pad
G (2) Mounting Screws with Anchors
H (1) Pigtail
Check to make sure everything in the package
matches the Contents Listing above. Read the
instructions thoroughly before installing or
operating the Floodstop system.
Warning: Do not put nger(s) inside Floodstop
Valves. Risk of serious injury may occur. Caution:
Do not grip plastic motor drive for leverage when
tightening Floodstop Valves.
STOP: Read the instructions thoroughly before installing or operating the Floodstop System. The Floodstop
Valves get installed directly to your existing valves. If you are not sure how to install the Floodstop Valves to
your existing water lines, we recommend that you contact a licensed Plumber.
WARNING:
For use with water only.
Do not install on gas line.
Installation
1. Shut o the hot and cold valves that supply water to your
washing machine.
2. Remove the hot and cold washing machine hoses from
both valves. Mark the hoses so you know which hose goes
to which valve. NOTE: Do not remove hoses from washing
machine.
3. Your existing hot and cold manual shut-o valves will have
outlets that either face you, or face downward.
A. If the outlets face you: Hand tighten the Floodstop
Valves to the manual shut-o valves so their outlets point
downward as shown in the diagram. Note that a washer
has been pre-assembled in each coupling nut.
B. If the outlets face downward: Hand tighten the Floodstop
Valves to the manual shut-o valves so their outlets point
sideways as shown in the diagram. Note that a washer
has been pre-assembled in each coupling nut.
4. Hand tighten the hot and cold washing machine hoses to the
correct Floodstop Valve.
5. Lightly wrench tighten all connections 1/4 turn, or until snug.
Do not over tighten.
6. Turn on the hot and cold manual shut-o valves and check
for leaks.
7. Mount the Floodstop Control Panel in an easily accessible
location within 30 inches of the Floodstop Valves. You may
mount the panel using the screws and anchors, or Hook & Loop
Mounting Pad provided. When using the Hook & Loop Mounting
Pad, make sure the adhesive is put on a clean, dry surface.
NOTE: Depending on the location you pick, and the distance
between the hot and cold shut-o valves, you may need to
purchase two (2) Floodstop Control Panel to Valve Extension
Wires, Model #FSACEXT9 (available where you purchased your
Floodstop System).
8. With the contacts of the wire harness connector facing you, plug
the 6-pin connector end of the Wire Harness into the bottom of
the Control Panel.
1
4
5
6
7
(NO) Output &
Sensitivity Adj
6 pin connector
8
valve
3A
valve
3B
2
A
B
C
D
E
H
F
G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Floodstop FS34H90 and is the answer not in the manual?

Floodstop FS34H90 Specifications

General IconGeneral
BrandFloodstop
ModelFS34H90
CategorySecurity Sensors
LanguageEnglish

Related product manuals