EasyManua.ls Logo

Fluid Filtration FG AF 72 G - User Manual

Default Icon
76 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Originalbetriebsanleitung mit Montageanleitung;
Translation of original instructions with installation instructions;
Traduction du mode d'emploi original avec notice d'assemblage
Automatik-Kantenspaltfilter mit Abstreiferabreinigung radial
Automatic Metal-Edge Filter with Radial Scraper Cleaning
Filtre à fentes automatiques avec nettoyage radial
AF 72 G
Mat-Nr. der Betriebsanleitung
Mat. No. of original instructions
N° d'identification du mode d'emploi
79718354

Table of Contents

Questions and Answers

  • J
    Jeffrey MurphyAug 7, 2025
    What to do if there's increased dirt concentration on the clean side of my Fluid Filtration Water Filtration Systems?
    • B
      Bradley BrownAug 7, 2025
      If you notice an increased concentration of dirt on the clean side of your Fluid Filtration Water Filtration System, it could be due to a defective filter element or brittle seals. Inspect the filter element and seals, and replace them if needed.
  • U
    uloganAug 13, 2025
    Why is the initial differential pressure no longer obtained in my Fluid Filtration FG AF 72 G?
    • E
      Elaine HughesAug 14, 2025
      If the initial differential pressure is no longer obtained in your Fluid Filtration Water Filtration System, it could be due to several reasons. The solids concentration might be too high, so improve the pre-filtration process. Alternatively, the gear motor might be rotating in the wrong direction, so check its rotation. It's also possible that the cleaning time is too short; try prolonging the cleaning time, ensuring the gear motor speed is at least 1-2 revolutions.
  • M
    Mark FreemanAug 18, 2025
    What to do if the valve does not open on Fluid Filtration FG AF 72 G Water Filtration Systems?
    • D
      David MckinneyAug 19, 2025
      If the valve on your Fluid Filtration Water Filtration System isn't opening, it could be due to low compressed air pressure; try increasing the pressure. Another possibility is a defective pilot valve, which you should check. Also, ensure the pilot valve is correctly connected, verifying both electrical and pneumatic connections.
  • K
    Kayla BrewerAug 26, 2025
    How to fix a gear motor that won't turn in Fluid Filtration FG AF 72 G?
    • S
      steven70Aug 26, 2025
      If the gear motor on your Fluid Filtration Water Filtration System isn't turning, it might be due to a tripped motor fuse. In this case, reset the motor fuse. Alternatively, the filtrate might have solidified, so you should clean the filter.
  • N
    newtonmichaelAug 31, 2025
    What to do if the leakage rate at the shaft seal is too high in Fluid Filtration Water Filtration Systems?
    • S
      Samuel HodgesAug 31, 2025
      If the leakage rate at the shaft seal of your Fluid Filtration Water Filtration System is too high, tighten the shaft seal. If the issue persists, replace the seal.

Summary

General Safety Instructions

Safety Instructions for Installation and Operating Personnel

Instructions for personnel involved in installation and operation.

Warning Structure

Explains the structure of warnings used in the manual.

Warning Symbols Used

Details the meaning of various warning symbols.

Glossary

General Information

Manufacturer

Information about the manufacturer.

User Information (Instruction Manual)

Details about the instruction manual.

Rating Plate ATEX

Information on the ATEX rating plate.

Intended Application

Functional Description

Principle of the Process

Explains the filtration and cleaning process.

Main Components of the Metal-Edge Filter

Lists and illustrates the main parts of the filter.

Functional Principle of a Metal-Edge Filter

Detailed explanation of how the metal-edge filter works.

Technical Data

Order-Specific Data

Technical specifications relevant to specific orders.

Order-Specific Data

More order-specific technical data.

Transport and Storage

Assembly Instructions

Mechanical Installation

Procedures for physically mounting the filter.

Special Installation Instructions for the Drain Pipe

Specific guidance for installing the drain pipe.

Electro-pneumatic Connections

Instructions for electrical/pneumatic connections, including customer/FG control.

Control Variants

Details time-controlled, differential pressure-controlled cleaning and draining options.

Start-up

Functional Test

Steps to perform functional tests after installation.

Programming the Operating Settings

How to program and configure the filter's operational settings.

Normal Operation

Shutting Down the Metal-Edge Filter

Temporary Shut-down

Steps for temporary shutdown.

Prolonged Shut-down (> 48 h)

Procedures for extended shutdowns.

Emergency Shut-down

Instructions for emergency shutdown procedures.

Troubleshooting

Maintenance

Inspection and Maintenance Schedule

Schedule for inspecting and maintaining the filter.

Removing the Filter Insert

Step-by-step guide to safely remove the filter insert.

Cleaning the Filter

Instructions for cleaning the filter insert and casing.

Replacing the Filter Element

Procedures for replacing the filter element.

Replacing the Scraper

Instructions for replacing the scraper component.

Replacing the Stuffing Box

Guide to replacing the stuffing box.

Spare Parts Drawing

List of Parts

List of Spare Parts

Declaration of Incorporation

Declaration of Conformity

Index

Fluid Filtration FG AF 72 G Specifications

General IconGeneral
BrandFluid Filtration
ModelFG AF 72 G
CategoryWater Filtration Systems
LanguageEnglish